Baldor MN1928 installation manual 5.2 BPL010-501 non-isolated backplane, Backplanes

Models: MN1928

1 126
Download 126 pages 18.49 Kb
Page 42
Image 42

www.supportme.net

5.2 BPL010-501 non-isolated backplane

This backplane provides direct connection to the NextMove ES signals without isolation. The electrical specifications of all signals are therefore the same as described in section 4.

In the following sections, the signals AGND, DGND and Shield are listed with nominal corresponding pins on the 96-pin connector, although they are all electrically connected on the backplane. The OUT COM pin on connector X11 is not connected to ground.

Some signals are duplicated on multiple identically named pins on the 96-pin connector. In these cases, only the lowest numbered pin is listed.

CAUTION: Some components are static sensitive devices. Take appropriate ESD precautions when handling the backplane.

 

 

 

 

DIN16

DIN17

DIN18

DIN19

DGND

 

DIN8

DIN9

DIN10

DIN11

DIN12

DIN13

DIN14

DIN15

DGND

Shield

 

 

 

 

 

 

 

 

X6

 

 

 

 

 

 

 

 

 

 

X13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIN0

DIN1

DIN2

DIN3

DIN4

DIN5

DIN6

DIN7

DGND

Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X12

 

 

 

X4

DOUT8

DOUT9

DOUT10

DOUT11

DGND

 

DOUT0

DOUT1

DOUT2

DOUT3

DOUT4

DOUT5

DOUT6

DOUT7

OUTCOM

DGND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Serial

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X5

 

 

 

 

 

 

 

 

 

X11

 

 

 

 

 

 

 

 

DGND

STEP2 -

STEP2+

DIR2 -

DIR2+

Shield

DGND

STEP3 -

STEP3+

DIR3 -

DIR3+

Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X10

 

 

 

 

 

 

 

 

DGND

STEP0 -

STEP0+

DIR0 -

DIR0+

Shield

DGND

STEP1 -

STEP1+

DIR1 -

DIR1+

Shield

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

X9

 

 

 

 

 

 

 

 

 

 

AIN0+

AIN0 -

AGND

AIN1+

AIN1 -

AGND

ERROR

!RSTIN

DGND

Shield

Encoder1

 

 

X2

Encoder0

 

X3

 

 

 

 

 

 

 

 

 

 

 

X8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+12V

-12V

+5V

DGND

DGND

 

 

 

DEM.0

AGND

Shield

DEM.1

AGND

Shield

DEM.2

AGND

Shield

DEM.3

AGND

Shield

 

 

 

 

 

X1

 

 

 

 

 

 

 

 

 

 

 

 

 

X7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 22 - Backplane BPL010-501 connector layout

5-2 Backplanes

MN1928

Page 42
Image 42
Baldor MN1928 installation manual 5.2 BPL010-501 non-isolated backplane, Backplanes, Backplane BPL010-501 connector layout