DS72 HOST MODULE OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

DETAILED OPERATION AND CONFIGURATION

The following section, “Detailed Operation and Configuration,” provides a detailed approach to accessing, operating, and configuring the DS72 network interface module.

NOTE: It is important that you type all commands correctly. Any combination of wrong entries results in an error message.

ACCESSING MAIN

Apply power to the module. The following header and main menu appear:

MENU

 

 

 

 

Data Switch Series - F.1.00

 

 

Bay Technical Associates

 

 

Unit ID: BAYTECH DS72

 

 

Port Select Code: $BT

 

 

Attention Character: ;

 

 

Device A

(2,1)

1

 

Device B

(2,2)

2

 

Device C

(2,3)

3

 

Device D

(2,4)

4

 

DS-RPC

(3,1)

5

 

Configure

C

 

Status

S

 

I/O Modules Reset

RM

 

Unit Reset

RU

 

Exit

X

 

Logout

T

Enter Request :

NOTE: Depending on the DS-Series model, the menus may vary according to the number of DS74 modules installed in the unit.

If this is not an initial set-up and Password has already been enabled, you are prompted to login. After logging in successfully, the main menu will appear.

NOTE: Password feature is case sensitive.

SELECTING A DEVICE There are two methods of selecting a device, menu driven selection and

 

ASCII character string method.

Menu Driven

From the main menu, select the number that corresponds to the device you

Selection

wish to access, followed by <cr>. To return to the main menu, send the

 

attention character five times (;;;;;).

ASCII Character

Another method of selecting devices and operating the DS-Series and DS

String

RPC is the ASCII character string method. To select a device located on

 

a peripheral Port, type $BTm,p where m is the module and p is the port.

 

To configure a module, type $BT and the module number followed by

8

Page 13
Image 13
Bay Technical Associates DS72 owner manual Detailed Operation and Configuration, Accessing Main, Menu