| DS72 HOST MODULE OWNER’S MANUAL |
| DETAILED OPERATION AND CONFIGURATION |
|
|
Login Setup : |
|
Header is | Enabled |
Password is | Disabled |
Menu is | Enabled |
Auto Connect Port is | Module 3,Port 1 |
Auto Connect is | Disabled |
SERIAL PORTDS72 modules perform data rate conversions for devices using
CONFIGURATION different serial configurations.See Appendix A, “SPECIFICATIONS” for available serial parameters. Default Serial Port Configurations are 9600 bps, 8 data bits, 1 stop bit, no parity, Xon/Xoff disabled, RTS high, and DTR low. From the configuration menu, select #2, “Serial Port Configuration”, followed by <cr>. The DS72 unit displays the following table:
|
|
| Module | 1 Serial Port Configuration : |
|
|
| ||||
Port | Device |
| Baud | Word |
| Stop | Parity | Xon/ | Xoff/ | Line | Drive |
| Name |
| Rate | Size |
| Bits |
| Xmit | Recv | DTR | RTS |
|
|
|
|
|
|
|
|
|
|
| |
1 | 9600 | 8 |
| 1 | None | Off | Off | High | High | ||
Save | 1 | Parity | 5 |
|
|
|
|
|
|
| |
Baud Rate..2 | Xon/Xoff | 6 |
|
|
|
|
|
|
| ||
Word Size..3 | RTS Line Driver... | 7 |
|
|
|
|
|
|
| ||
Stop bits..4 | DTR Line Driver... | 8 |
|
|
|
|
|
|
|
Enter Request :
Select the corresponding number to configure baud rate, word size, stop
bits, parity...
NOTE: DTR is unchangeable when configuring the serial port.
For example, to change the baud rate to 115.2K, select #2, “Set Baud Rate,” followed by <cr>.
The DS71 displays the following list of available baud rates:
1 for 300
2 for 600
3 for 1200
4 for 2400
5 for 4800
6 for 9600
7for 19200
8for 38400
9 for 57.6K A for 76.8K B for 115.2K Enter Request :
Type "B" for 115.2K baud rate. The DS72 responds with the new configuration status:
11