DS72 HOST MODULE OWNER’S MANUAL

 

DETAILED OPERATION AND CONFIGURATION

 

 

Login Setup :

 

Header is

Enabled

Password is

Disabled

Menu is

Enabled

Auto Connect Port is

Module 3,Port 1

Auto Connect is

Disabled

SERIAL PORTDS72 modules perform data rate conversions for devices using

CONFIGURATION different serial configurations.See Appendix A, “SPECIFICATIONS” for available serial parameters. Default Serial Port Configurations are 9600 bps, 8 data bits, 1 stop bit, no parity, Xon/Xoff disabled, RTS high, and DTR low. From the configuration menu, select #2, “Serial Port Configuration”, followed by <cr>. The DS72 unit displays the following table:

 

 

 

Module

1 Serial Port Configuration :

 

 

 

Port

Device

 

Baud

Word

 

Stop

Parity

Xon/

Xoff/

Line

Drive

 

Name

 

Rate

Size

 

Bits

 

Xmit

Recv

DTR

RTS

 

 

 

 

 

 

 

 

 

 

 

1

EIA-232

9600

8

 

1

None

Off

Off

High

High

Save

1

Parity

5

 

 

 

 

 

 

 

Baud Rate..2

Xon/Xoff

6

 

 

 

 

 

 

 

Word Size..3

RTS Line Driver...

7

 

 

 

 

 

 

 

Stop bits..4

DTR Line Driver...

8

 

 

 

 

 

 

 

Enter Request :

Select the corresponding number to configure baud rate, word size, stop

bits, parity...

NOTE: DTR is unchangeable when configuring the serial port.

For example, to change the baud rate to 115.2K, select #2, “Set Baud Rate,” followed by <cr>.

The DS71 displays the following list of available baud rates:

1 for 300

2 for 600

3 for 1200

4 for 2400

5 for 4800

6 for 9600

7for 19200

8for 38400

9 for 57.6K A for 76.8K B for 115.2K Enter Request :

Type "B" for 115.2K baud rate. The DS72 responds with the new configuration status:

11

Page 16
Image 16
Bay Technical Associates DS72 owner manual For For 57.6K a for 76.8K B for 115.2K Enter Request