P72895_F1D104-OSD-univ_man.qxd 7/16/01 3:24 PM Page 9

Hardware Installation (continued)

NOTE: Avoid pressing any keys on the keyboard or moving the mouse if the currently selected port has a computer that is in the process of booting up. This may cause the computer to not detect, or initialize the keyboard or mouse drivers properly.

Daisy-Chaining the OmniViewPRO:

The OmniViewPRO can be daisy-chained with additional OmniViewPRO units through the

DB25 daisy-chain ports. The F1D108-CBL daisy-chain cable is required (not included) for proper En operation. Please refer to the example below. Here, four OmniViewPRO units are cascaded together for control of 16 computers. Recall that a maximum of 4 OmniViewPRO units can be cascaded together for control of 16 computers. Recall that the DIP switches on the MASTER

unit must be set to BANK 0, and the slave units set to a unique BANK (any from 1 through 3). See the beginning of this section for more information on the DIP switch settings.

MASTER (Bank 0)

Cable 1

slave

(Bank 1)

Cable 2

slave

(Bank 2)

Cable 3

slave

(Bank 3)

After setting the DIP switches on the slave unit, connect the computers using the same procedure outlined in steps 4 to 8 in the previous section. DO NOT POWER UP THE COMPUTERS YET.

Using the F1D108-CBL daisy-chain cable, connect one end to the Master Input/Slave Output of the unit. Refer to the diagram above.

If the previous unit is the MASTER, then the other end of the cable connects to the Master Input/Slave Output port of the MASTER (such as cable 1 in the diagram above).

If the previous unit is a slave, then the other end goes to the Slave Input port of the previous slave unit (such as cables 2 and 3 in the diagram above).

Upon connecting the daisy-chain cable to the previous unit, it should automatically power up if the previous unit is powered up. However, it is still recommended that the power supply be used with the slave unit. You will see the LED display on the front panel show the units bank address setting.

9

Page 13
Image 13
Belkin F1D104-OSD user manual Daisy-Chaining the OmniView PRO