I N STA L L AT I O N
Example of Daisy-Chain Configuration:
Slave Input
VGA | VGA08 | USB 08 | VGA07 | 06 | VGA 06 | USB 06 | VGA05 | VGA04 | USB 04 | VGA03 | VGA | 02 | USB 02 | VGA01 |
Master Input /Slave Output |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 08 | USB 07 | 07 |
| 06 | USB 05 | 05 | 04 | USB 03 | 03 | 02 |
| USB 01 | 01 |
cable 1 |
| Master unit | (BANK 00) |
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Slave Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VGA | VGA08 | USB 08 | VGA07 | 06 | VGA 06 | USB 06 | VGA05 | VGA04 | USB 04 | VGA03 | VGA | 02 | USB 02 | VGA01 |
Master Input /Slave Output |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 08 | USB 07 | 07 |
| 06 | USB 05 | 05 | 04 | USB 03 | 03 | 02 |
| USB 01 | 01 |
|
|
| Slave unit |
| (BANK 01) |
|
|
|
|
| ||||
cable 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Slave Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VGA | VGA08 | USB 08 | VGA07 | 06 | VGA 06 | USB 06 | VGA05 | VGA04 | USB 04 | VGA03 | VGA | 02 | USB 02 | VGA01 |
Master Input /Slave Output |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 08 | USB 07 | 07 |
| 06 | USB 05 | 05 | 04 | USB 03 | 03 | 02 |
| USB 01 | 01 |
cable 3 |
|
| Slave unit |
| (BANK 02) |
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
Slave Input |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VGA | VGA08 | USB 08 | VGA07 | 06 | VGA 06 | USB 06 | VGA05 | VGA04 | USB 04 | VGA03 | VGA | 02 | USB 02 | VGA01 |
Master Input /Slave Output |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 08 | USB 07 | 07 |
| 06 | USB 05 | 05 | 04 | USB 03 | 03 | 02 |
| USB 01 | 01 |
|
|
| Slave unit |
| (BANK 03) |
|
|
|
|
|
Connecting the Computers:
9.Connect all computers to the Master and Slave switches. Refer to “Single PRO2 Installation” on page 10 for instruction on how to connect the Console and the computers to the PRO2.
10.Connect the power supply to the Master switch. Power up the Master switch. You should see the Master switch light up and display the digits “00”, indicating its BANK address.
11.Power up the Slave switches sequentially, beginning with Bank 01, by connecting each unit’s power supply. Each switch should display its corresponding BANK address number as it is powered up.
Note: If the PRO2s do not enumerate correctly, reset the Master switch (BANK 00) by simultaneously pressing the "BANK +" and "BANK
If the switches still do not enumerate correctly, check that all switches have the correct BANK address assigned to them and that all
12.Verify that the Master unit has detected all Slave switches by scrolling through the BANKS using the BANK up and BANK down buttons.
If all Slave switches are detected properly, the LED display on the Master switch will register and display the attached Slave switch’s BANK address.
15