7. Use the handle to slowly pull lamp housing out of the projector.

• Pulling it too quickly may cause the lamp to break and scatter

broken glass in the projector.

 

2

• Do not place the lamp in locations where water might splash on

2

 

it, children can reach it, or near flammable materials.

 

1

• Do not insert your hands into the projector after the lamp is

 

 

 

removed. If you touch the optical components inside, it could

 

 

cause color unevenness and distortion of the projected images.

 

 

8. Carefully lower the new lamp housing to slide it from left to

 

right into the lamp compartment, as illustrated.

 

• Be careful not to damage the sides of the new lamp housing

 

while lowering the whole assembly.

1

1

 

 

2

9.

Tighten the screw that secures the lamp.

2

10.

Ensure the handle is fully laid flat and locked in place.

Loose screw may cause a bad connection, which could result in

 

 

malfunction.

3

Do not over tighten the screw.

 

1

11. Replace the lamp cover on the projector.

21

12. Tighten the screw that secures the lamp cover.

• Loose screw may cause a bad connection, which could result in malfunction.

• Do not over tighten the screw.

13. Connect the power and restart the projector.

Resetting the lamp timer

Do not reset the lamp timer if the lamp has not been replaced as this could cause damage.

14.After the start-up logo, press MENU/EXIT and then press / until the Advanced Setup menu is highlighted.

15.Press to highlight Lamp Settings and press MODE/ENTER. The Lamp Settings page displays.

16.Highlight Reset Lamp Timer and press MODE/ENTER. A warning message displays asking if you want to reset the lamp timer. Highlight Reset and press MODE/ENTER. The lamp time will be reset to "0".