English

Indicators

There are three indicators which show the status of the projector. Check the following for information about the indicator lights. If there is anything wrong, turn the projector off and contact your dealer.

When the projector is in a normal state

 

 

Power

Temp

Lamp

 

Status & Description

 

 

Orange

Off

Off

Stand-by mode

 

 

 

 

 

 

 

 

 

 

 

Green

Off

Off

Powering up

 

 

 

Flashing

 

 

 

 

 

 

 

 

 

 

Green

Off

Off

Normal operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The projector needs 90 seconds to cool down as it was

 

 

Orange

 

 

 

abnormally shut down without the normal cooling down

 

 

Off

Off

 

process.

 

 

 

Flashing

 

 

 

 

 

 

• The projector needs to cool for 90 seconds after the power is

 

 

 

 

 

 

 

 

 

 

 

turned off.

 

 

 

 

 

 

 

 

 

 

 

When the projector is in an abnormal state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power

Temp

Lamp

 

Status & Description

 

 

Off

Off

Red

 

• The lamp has been damaged. Please contact your local BenQ

 

 

 

customer center for purchasing a new lamp.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• The lamp is not properly attached.

 

 

Orange

Off

Red

 

• The lamp has been damaged. Please contact your local BenQ

 

 

 

 

 

 

customer center for purchasing a new lamp.

 

 

 

 

 

 

 

 

 

 

Off

Red

Off

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Red

Red

 

The fans are not working.

 

 

 

 

 

 

 

 

 

 

Off

Red

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Red

Orange

 

 

 

 

 

 

 

 

 

 

 

 

 

Off

Green

Red

 

Fan sensors error

The projector has shut down

 

 

Off

Green

Orange Fans do not rotate during

 

 

automatically. If you try to re-

 

 

 

 

 

 

powering up.

 

 

Off

Orange

Red

 

start the projector, it will shut

 

 

 

 

 

 

 

down again. Please contact your

 

 

Red

Red

Red

 

 

 

 

 

 

 

 

 

dealer for assistance.

 

 

Red

Red

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Red

Red

Orange

 

Thermal condition error

 

 

 

 

 

 

 

 

 

 

Green

Red

Red

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

Red

Green

 

 

 

 

 

 

 

 

 

 

 

 

 

Green

Red

Orange

 

 

 

 

 

 

 

 

 

 

 

 

 

Orange

Red

Red

 

The internal temperature is too high.

 

 

 

 

 

 

 

 

 

 

Orange

Red

Green

 

• The intake ventilation or the exhaust ventilation is blocked.

 

 

 

 

 

 

 

 

Orange

Red

Orange

 

• The projector may be in a poorly ventilated location.

 

 

 

 

 

The ambient temperature may be too high.