A/C-7P RO, A/C-7S RO

3.Send that command to the printer (press the Print Screen Button or print the document/file that contains the Host/PC download command).

4.Send the host data in question to the printer.

5.To stop the EBCDIC hex dump, type “&%Z42,2” on the screen, then send it to the printer (press the Print Screen Button or print the document/file that contains the Host/PC download command).

Start the EBCDIC hex dump from the A/C-7 RO’s front panel as follows:

1.With the A/C-7 RO powered on, set configuration switch SW1:1 (far left) to “o”, and switch SW1:8 (far right of first switch bank) to “”. The A/C-7 RO is now in buffer print mode.

2.Return configuration switch SW1:8 to the “o” position after printing is completed.

7.3 ASCII Hex Dump

The A/C-7 RO can be set up to print the buffer in hexadecimal ASCII code. This differs from the EBCDIC hex dump in that the buffer is first translated into ASCII code before it is printed. This can be useful to diagnose problems with the interface or the printer. The ASCII Hex Dump can only be started through the A/C-7 RO’s configuration switches. To start the ASCII Hex Dump:

1.Locate configuration switches SW1:4, SW1:5, SW1:6, and SW1:7 on the first switch bank.

2.Write down their current position (“o” or “”).

3.With the A/C-7 RO powered on, set the configuration switches SW1:4, SW1:5, SW1:6, and SW1:7 to “”. The A/C-7 RO is now in ASCII Hex Dump mode.

4.To end ASCII Hex Dump mode, return the switches to their original position (see Step 2).