COMMAND 34: INTERVENTION REQUIRED (IR) TIMEOUT

A/C-7P RO, A/C-7S RO

COMMAND 34: INTERVENTION REQUIRED (IR) TIMEOUT

Sets the time interval before an intervention required signal is sent to the host after a printer error occurs.

VALUE

DESCRIPTION

000

Never send an IR

001

IR is sent (value *5)

to

seconds after

255

printer error occurs

*120

Default, send IR

 

after ten minutes.

Example: &%Z34,036 sets IR time interval to 3 minutes (36 *5)/60 = 3 minutes.

COMMAND 36: SUPPRESS IBM CONTROL CODES

This function is used to select suppression of all or some IBM control codes sent from the host system.

VALUE

DESCRIPTION

*0

Obey all IBM

 

control codes

1Suppress all IBM control codes

2Suppress LPI, CPI, MPP and MPL control codes

3Suppress CPI and MPP control codes

4Suppress LPI and MPL control codes

5Suppress print quality specified in the PPM command

*Factory-default setting.

NOTES

If this command is set to 1, documents need to be formatted by sending transparent control codes to the printer using Command Pass-Thru or SCS mode transparent data.

If value 2 is selected, the SCS pitch (CPI), line density (LPI), SHF (MPP), and SVF (MPL) commands will be suppressed (not sent to the printer).

Example: &%Z36,2 no LPI, CPI, MPP or MPL commands are sent to the printer. The document prints using the printer’s defaults.

COMMAND 37: VERTICAL CHANNEL SELECT (VCS)

Specifies vertical channel select (VCS) emulation. Functions similarly to a vertical tab, except the 3287 does LF only.

VALUE DESCRIPTION

03287 VCS emulation

*1

3268/4214/4224

 

VCS emulation

Example: &%Z37,0 selects 3287 VCS emulation.