4.4Host/PC Download Command Overview

A/C-7P RO, A/C-7S RO

1.Type the Command Pass-Thru delimiter &% (or alternate CPT beginning delimiter) in the document at the point where the command is to take effect.

2.Type an upper case “Z” (or the alternate command ID character).

3.Type the command number for the command to be used, as shown in the table.

4.Type a comma.

5.Type the value representing the desired selection. No spaces are allowed. A space or invalid character in a command causes the A/C-7 RO to ignore the command and resume printing from the point the error occurred.

6.A space or control character (NL, LF, CR, or FF) signals the end of the download command.

7.Multiple commands can be chained together by using a slash

(/) or backslash (\) to separate the commands (no spaces allowed). For example, to set the Form Length (Command 05) to 64 lines (Value 64), the Buffer Size (Command 01) to 960 characters (Value 1), and the Character Density (Command

03) to 12 CPI (Value 12), type:

&%Z05,64/Z01,1/Z03,12

4.4Host/PC Download Command Overview

Table 4-10shows the Coax Host/PC Download commands and their corresponding command numbers in alphabetical order: