A/C-7P RO, A/C-7S RO

COMMAND 77: SERIAL-IN WORD LENGTH

Selects the Word Length of data received at the serial-in port. A new setting will not be effective immediately. To activate the new setting, cycle power on the interface.

VALUE

DESCRIPTION

7

7 Bits

*8

8 Bits

Example: &%Z77,7 sets the word length to 7 bits

COMMAND 78: SERIAL-IN STOP BITS

Selects the number of Stop Bits of a data stream received at the serial-in port. A new setting will not be effective immediately. To activate the new setting, cycle power on the interface.

VALUE

DESCRIPTION

*1

1

Bit

2

2

Bits

Example: &%Z78,2 sets the number of Stop Bits to 2

*Factory-default setting.

COMMAND 79: SERIAL-IN PARITY

Selects the Parity of a data stream received at the serial-in port. A new setting will not be effective immediately. To activate the new setting, cycle power on the interface.

VALUE

DESCRIPTION

*0

None

1Odd

2Even

Example: &%Z79,2 sets the parity to even.

COMMAND 84: 6 LPI STRING

Used when operating in Generic output protocol. Defines the 6 LPI string the interface sends to the printer when the host sends a 6 LPI command.

VALUE

DESCRIPTION

1(max. 25

Defines the 6 LPI

bytes of

string

ASCII hex

 

code)

 

1()

Deletes the 6 LPI

 

string

53

Page 52
Image 52
Black Box A/C-7S RO manual Command 77 SERIAL-IN Word Length, Command 78 SERIAL-IN Stop Bits, Command 79 SERIAL-IN Parity