APPENDIX: Cable Pinning/Pairing

APPENDIX: Cable Pinning/Pairing

Appendix: Cable Pinning/Pairing

The cable you will use to interconnect the Local and Remote Units of your ServSwitch™ Brand CAT5 KVM Micro Extender should be terminated with RJ-45 plugs and should be wired according to the EIA/TIA-568 standard (preferably 568B rather than 568A). See Section 4.2.5 for a more complete set of cable recommendations.

Looking into the interconnect socket on either Micro Extender Unit, or looking at the cable plug from behind, Pin 1 should be on the left and Pin 8 on the right, and the wires should be arranged this way:

Pin

Color

Function, Pair

1

White/Orange

TX, Pair 2

2

Orange/White

RX, Pair 2

3

White/Green

TX, Pair 3

4

Blue/White

RX, Pair 1

5

White/Blue

TX, Pair 1

6

Green/White

RX, Pair 3

7

White/Brown

TX, Pair 4

8

Brown/White

RX, Pair 4

NOTES

The Micro Extender has been tested with all major makes of CAT5 cable including Black Box, Berk-Tek, Mohawk®, and AT&T®. The Extender has also been tested and found to work, in certain situations, with 4-pair Category 3 cable or with four pairs of 25-pair UTP trunk cables instead of 4-pair Category 5 cable. But we do not recommend such installations; if you want to experiment with them, do so at your own risk.

We don’t recommend using CAT5e cable, but it might work in some applications. Avoid using cables rated “Level 6,” “Level 7,” etc.