Bosch Appliances D5500CU manual 3Upgrade from RPS 5.11 or Lower, Create a New Database

Models: D5500CU

1 78
Download 78 pages 2.28 Kb
Page 48
Image 48

48 en Upgrade RPSRPS

4.4.3Upgrade from RPS 5.11 or Lower

If upgrading from RPS 5.11 or lower, the DAT Files Integration window opens when you click Upgrade Database on the File Locations tab.

If the path shown in the DAT Files Integration window matches the location of the RPS database files, click OK.

If the path shown in the DAT Files Integration window does not match the path to where the new SQL database is installed, click Browse, and navigate to the location of the new SQL database. Then click OK.

All existing RPS .dat files are copied from their current location to the new SQL database location.

4.4.4

Create a New Database

 

If the SQL database fails to upgrade automatically, click Create Database on the File

 

Locations tab to merge the existing database with a new database.

4.4.5

Conversion Log File

 

If an RPS .dat file does not exist in the database folder, RPS copies a corresponding default

.dat file to the new SQL database location. RPS then creates a DATFileConversion.log file in X:\RPS\Logs (“X” = the drive letter associated to the drive where RPS is installed).

This log file consists of the following information:

– The date and time that the conversion occurred

– The versions that RPS was upgraded from and to

– The location of the RPS .dat files before the conversion started

– The conversion results

Below is a sample conversion file log:

To view the DATFileConversion.log file, click View Conversion Log on the DAT File

Integration Results window.

4998141259 12 2011.10

Installation Guide

Bosch Security Systems, Inc.

Page 48
Image 48
Bosch Appliances D5500CU manual 3Upgrade from RPS 5.11 or Lower, Create a New Database, Conversion Log File