72 en RPS Operation and Control Panel Account NotesRPS
– Tamper conditions not bypassable
bypasses the alarm condition. Tamper conditions cannot be bypassed.
– Remote Programming Lockout
| attempts to connect to the control panel from RPS, the control panel locks out any |
| remote programming sessions for 4 h. Remote programming through the direct connect |
| method is still available. |
| – SRT Modems |
| not work with the |
| Config Modem tab. |
7.2.3 | D7024 and DS9400 |
| – Firmware Revision: To program the FACP using RPS, the FACP must have firmware |
| version 2.02 or later installed. |
| – Firmware 2.04 Defaults: The default account values are intended for firmware 2.04. A |
| "Panel out of Sync" message appears if you connect to a control panel with firmware |
| version 2.03 or lower. |
| – False Values/Blank Results Appear in Compare Window: If a |
| installed and "Receive Panel Data" is selected from the Panel Sync dialog, some of the |
| values for Zones 5 to 8 might not be retrieved correctly. If a |
| installed, the values for Input Points 5 to 8 are retrieved correctly. |
| – Gentex RNAC Option: The Gentex NAC output configuration is a valid NAC option on |
| control panels with firmware version 2.04 or later. If Gentex is selected and sent to a |
| control panel with firmware version 2.03 or lower, the NAC response is set to Steady. |
| – Remote Program Enabled: If "Remote Program Enabled" is set to No, RPS still allows you |
| to receive data from the control panel; however, for security reasons, you cannot view |
| any of the PINs or change any program information. |
| – "Panel out of Sync" Message with Defaulted DS9400M and RPS: The RPS default for |
| MUX Bus Type is "Not Installed," whereas the DS9400M's default is "Installed." |
7.2.4 | D8112 |
| – Panel Sync Window: D8112 Series Control Panels always show a Panel Sync dialog even |
| if the data in RPS matches the data in the control panel. |
| – Importing Zone Notes from a RAM II Account (D8112G, G1, G2): Zone notes entered for |
| Zones 100+ do not appear with their appropriate zone when imported into RPS. Zone |
| notes must be manually entered into RPS. This is because RAM II does not account for |
| Master Zones in the Zones table. |
7.2.5 | D9112B1, D7212B1 |
| – Panel Sync Window Appears with Defaulted Panel and Account (D7212B1 only): The |
| Panel Sync dialog should only appear when there are programming differences between |
| the control panel and the RPS account; however, it might appear if you connect to a |
| defaulted control panel with a defaulted RPS account. Comparing the defaulted control |
| panel and RPS account yields no default differences. |
– ZOOM 2949 56Kx Zoom Fax Modem Answer Ring Setting: Set the control panel's answer ring count to answer on less than eight rings when using the ZOOM 2949 56Kx Zoom Fax Modem (version 34X).
– Message Limitation (Keypad Tab): Even though you can send messages to each keypad's (command center) address, only one message can be performed at a time.
4998141259 12 2011.10 | Installation Guide | Bosch Security Systems, Inc. |