Tamper conditions not bypassable (DS7240-UK only): Bypassing a zone from RPS only

bypasses the alarm condition. Tamper conditions cannot be bypassed.

Remote Programming Lockout (DS7240-UK and DS7200V2-UK only): After three invalid

 

attempts to connect to the control panel from RPS, the control panel locks out any

 

remote programming sessions for 4 h. Remote programming through the direct connect

 

method is still available.

 

SRT Modems (DS7240-NOR only): The SRT MiniBox and SRT ProBox 33.6 modems do

 

not work with the DS7240-NOR control panel even though they appear in the System

 

Config Modem tab.

7.2.3

D7024 and DS9400

 

Firmware Revision: To program the FACP using RPS, the FACP must have firmware

 

version 2.02 or later installed.

 

Firmware 2.04 Defaults: The default account values are intended for firmware 2.04. A

 

"Panel out of Sync" message appears if you connect to a control panel with firmware

 

version 2.03 or lower.

 

False Values/Blank Results Appear in Compare Window: If a four-zone expander is not

 

installed and "Receive Panel Data" is selected from the Panel Sync dialog, some of the

 

values for Zones 5 to 8 might not be retrieved correctly. If a four-zone expander is

 

installed, the values for Input Points 5 to 8 are retrieved correctly.

 

Gentex RNAC Option: The Gentex NAC output configuration is a valid NAC option on

 

control panels with firmware version 2.04 or later. If Gentex is selected and sent to a

 

control panel with firmware version 2.03 or lower, the NAC response is set to Steady.

 

Remote Program Enabled: If "Remote Program Enabled" is set to No, RPS still allows you

 

to receive data from the control panel; however, for security reasons, you cannot view

 

any of the PINs or change any program information.

 

"Panel out of Sync" Message with Defaulted DS9400M and RPS: The RPS default for

 

MUX Bus Type is "Not Installed," whereas the DS9400M's default is "Installed."

7.2.4

D8112

 

Panel Sync Window: D8112 Series Control Panels always show a Panel Sync dialog even

 

if the data in RPS matches the data in the control panel.

 

Importing Zone Notes from a RAM II Account (D8112G, G1, G2): Zone notes entered for

 

Zones 100+ do not appear with their appropriate zone when imported into RPS. Zone

 

notes must be manually entered into RPS. This is because RAM II does not account for

 

Master Zones in the Zones table.

7.2.5

D9112B1, D7212B1

 

Panel Sync Window Appears with Defaulted Panel and Account (D7212B1 only): The

 

Panel Sync dialog should only appear when there are programming differences between

 

the control panel and the RPS account; however, it might appear if you connect to a

 

defaulted control panel with a defaulted RPS account. Comparing the defaulted control

 

panel and RPS account yields no default differences.

ZOOM 2949 56Kx Zoom Fax Modem Answer Ring Setting: Set the control panel's answer ring count to answer on less than eight rings when using the ZOOM 2949 56Kx Zoom Fax Modem (version 34X).

Message Limitation (Keypad Tab): Even though you can send messages to each keypad's (command center) address, only one message can be performed at a time.

4998141259 12 2011.10