20 en Installation

IP Camera 200 Series

 

 

3.5I/O connector

1

 

 

 

 

 

2

 

 

 

 

 

3

 

 

 

 

 

4

 

 

 

I/O

 

 

 

 

Line-

DC12V

 

erne

 

 

 

 

out

Reset

Eth

 

 

t

 

 

 

 

 

 

 

 

Line-

 

 

 

 

 

in

5 mm

(0.2 in)

Figure 3.5 I/O connector pins

I/O

Pin 1

Pin 4

Function

Pin

I/O socket

 

 

 

Relay

1

Relay out contact 1

 

 

 

 

2

Relay out contact 2

 

 

 

Alarm input

3

Relay in Positive

 

 

 

 

4

Relay in Negative

 

 

 

Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation.

Relay output switching capability: Max. voltage 24 VAC or 24 VDC. Max. 1 A continuous, 12 VA.

Trigger in: +9 VDC minimum; +30 VDC maximum. Reverse polarity connection will be inactive.

Alarm input configurable as active low or active high.

AR18-10-B012 v1.5 2011.01