52 en Advanced Mode

IP Camera 200 Series

 

 

6.4.3Encoder Streams

Select H.264 Settings

1.The codec algorithm for stream 1 is always:

H.264 MP 720p25/30 fixed

2.Select the codec algorithm for stream 2. The following are available:

Copy Stream 1

H.264 BP+ bit-rate-limited

H.264 MP SD

3.Select the default profile for each stream from the eight profiles that have been defined.

Preview >>

Previews of streams 1 and 2 can be shown.

1.Click Preview >> to display a preview of the video for streams 1 and 2. the current profile is shown above the preview.

2.Click 1:1 Live View below a preview to open a viewing window for that stream. Various additional items of information are shown across the top of the window.

3.Click Preview << to close the preview displays.

Note:

Deactivate the display of the video images if the performance of the computer is adversely affected by the decoding of the data stream.

JPEG stream

Set the parmeters for the M-JPEG stream.

Select the Max. frame rate in images per second (IPS).

The Picture quality slider allows adjustment of the M-JPEG image quality from Low to High.

Note:

The M-JPEG resolution follows the highest resolution setting of either stream 1 or stream 2. For example, if stream 1 is VGA and stream 2 is QVGA, the JPEG resolution will be VGA. The M-JPEG frame rate varies depending on system loading.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Page 52