6.7Interfaces

80 en Advanced Mode

IP Camera 200 Series

 

 

6.7Interfaces

Interfaces

>Alarm input

>Relay

6.7.1Alarm input

Configure the alarm trigger for the camera.

Select N.C. (Normally Closed) if the alarm is to be triggered by opening the contact.

Select N.O. (Normally Open) if the alarm is to be triggered by closing the contact.

Name

Enter a name for the alarm input. This name can be displayed below the icon for the alarm input on the LIVEPAGE. (Do not use any special characters, for example &.)

6.7.2Relay

Configure the switching behavior of the relay output.

Select different events that automatically activate an output. For example, turn on a floodlight by triggering a motion alarm and then turn the light off again when the alarm has stopped.

Idle state

Select Open for the relay to operate as an N.O. contact, or select Closed if the relay is to operate as an N.C. contact.

Operating mode

Select an operating mode for the relay.

For example, if you want an alarm-activated lamp to stay on after the alarm ends, select Bistable. If you wish an alarm- activated siren to sound for ten seconds, for example, select

10 s.