86 en Advanced Mode

IP Camera 200 Series

 

 

6.8.2Advanced

The settings on this page are used to set advanced settings the network. Some changes only take effect after a reboot. In this case Set changes to Set and Reboot.

1.Make the desired changes.

2.Click Set and Reboot.

The device is rebooted and the changed settings are activated.

SNMP

The camera supports the SNMP V2 (Simple Network Management Protocol) for managing and monitoring network components, and can send SNMP messages (traps) to IP addresses. It supports SNMP MIB II in the unified code.

If On is selected for the SNMP parameter and a SNMP host address is not entered, the device does not send the traps automatically and will only reply to SNMP requests. If one or two SNMP host addresses are entered, SNMP traps are sent automatically. Select Off to deactivate the SNMP function.

1. SNMP host address / 2. SNMP host address

To send SNMP traps automatically, enter the IP addresses of one or two target devices here.

SNMP traps

To choose which traps are sent:

1.Click Select. A dialog box appears.

2.Click the check boxes of the appropriate traps.

3.Click Set to close the window and send all of the checked traps.

Authentication (802.1x)

To configure Radius server authentication, connect the camera directly to a computer using a network cable. If a Radius server controls access rights over the network, select On to activate authentication to communicate with the device.

1.Enter the user name that the Radius server uses for the camera in the Identity field.

2.Enter the Password that the Radius server expects from the camera.

AR18-10-B012 v1.5 2011.01

Installation and Operation Manual

Bosch Security Systems

Page 86
Image 86
Bosch Appliances NDC-265-P operation manual Advanced, Snmp host address / 2. Snmp host address, Snmp traps, Authentication