3.5I/O connector

IP Camera 200 Series

Installation en 19

 

 

3.5I/O connector

1 2 3 4

DC 12V

Ethernet

Line-out

Line-in

5 mm

Pin

(0.2 in)

1

 

2

 

3

 

4

I/O

Relay out

Relay in

Figure 3.4 I/O connector pins

Function

Pin

I/O socket

 

 

 

Relay

1

Relay out

 

 

 

 

2

Relay out

 

 

 

Alarm input

3

Relay in

4Relay in

Max. wire diameter AWG 22-28 for both stranded and solid; cut back 5 mm (0.2 in) of insulation.

Relay output switching capability: Max. voltage 24 VAC or 24 VDC. Max. 1 A continuous, 12 VA.

Relay in: Short or +5 VDC activation.

Alarm input configurable as active low or active high.