33.
Troubleshooting
Troubleshooting Guide - Electrical
PROBLEM
Brake does not stop blade in
about 5 seconds
Motor does not start.
Flash of light from motor end-
cap when switch is released.
CAUSE
1. Brushes not seated or lightly
sticking or worn.
2. Motor overheated from use
of dull blade/too heavy of a
blade, not recommended
accessory or rapid on/off
cycling.
3. Blade bolt loose.
4. Other
1. Check that unit is plugged in.
2. Power source fuse or
time delay fuse.
3. Brushes worn.
4. Other.
1. Normal - brake
working properly.
CORRECTIVE ACTION
Inspect/clean or replace
brushes (see Maintenance
Section).
Use sharp blade.
Use a recommended blade.
Let saw cool down.
Tighten blade bolt.
Authorized service
Plug unit in. Use different
outlet.
15-Amp time delay fuse or
circuit breaker.
See Brush Replacement in
the Maintenance and Lubri-
cation section.
Authorized service.
None required.

Note: To find an authorized service center,

call 1-877-BOSCH99 (1-877-267-2499)

or visit www.boschtools.com.