TM
SLE100 Installation Manual
•Quality Voltages between 0.5V and 1.0V indicate excessive errors in the wireless link that can not be corrected by the FEC. To indicate this change in error performance, the quality voltage will drop from 1.5V to 1.0V in a single step.
•Quality Voltages below 0.5V indicate an unlocked deframer condition. This will be recognized as a
The following procedure can be used to check the RSL and quality voltages:
1.To read the RSL value (between 0 and 3.3V), insert GND (ground) and RSL banana plugs into the voltmeter. Note the RSL voltage. The voltage may be fluctuating; in this case, note the maximum value seen.
2.To read the Link Quality value of the radio, insert GND (ground) and QUAL banana plugs into the voltmeter. Note the Link Quality voltage. After an
The SLE100 has been designed to require only minimal user configuration. To perform the configuration of the Network Management System follow the instructions in the Network Management manual.
During normal operation, the following conditions should exist at the radio:
•The power LED should be
•The Link Up LED should be
•The Link Quality BER voltage should be 3.3v, although dips in voltage are acceptable during periods of significant rain.
•Observe the
Figure 3-14: Radio Link Up and Power LED’s
29 |