Table 1: Serial Interface Parameters Settings

Selector

Parameters

On (up)

Off (down)

1

Baud Rate

See Table 2

 

2

Baud Rate

See Table 2

 

3

Data Length

7 bits

8 bits

4

Stop Bit

2 bits

1 bit

5

Parity

See Table 3.

 

6

Parity

See Table 3.

 

7

Protocol

Xon/Xoff + DTR

DTR only

8

Robust Xon

On

Off

Table 2: Baud Rate Settings

 

 

 

 

 

 

Selector 1

Selector 2

For RS-422A

For RS-232C

Off

Off

57600

9600

On

Off

9600

4800

Off

On

1200

1200

On

On

19200

19200

Table 3: Parity Settings

 

 

 

 

 

 

Selector 5

Selector 6

Parity

 

On

On

Odd

 

On

Off

Even

 

Off

Off

None

 

Note

The factory settings are indicated in bold ( all switches OFF ).

If the robust Xon setting is turned on with selector 8, the printer sends Xon signals at one second intervals to the connected computer until it receives data. It is effective only if selector 7 is set to the On position for the Xon/Xoff plus DTR setting.

2-6