Bryant 580G manual Ð Evaporator Fan Motor Data, A. Positioning, B. Roof Mount, B. 580H Units

Models: 580G

1 44
Download 44 pages 8.75 Kb
Page 7
Image 7
Table 2 Ð Evaporator Fan Motor Data

Table 2 Ð Evaporator Fan Motor Data

 

 

MOTOR

FAN

 

MOTOR

 

 

FAN

 

 

 

BELT

UNIT

 

 

SHEAVE

BUSHING

 

SHEAVE

BUSHING

 

OUTSIDE

MOTOR

SHAFT

SHAFT

MOTOR

FAN

BELT

TENSION

SIZE

PITCH

DIAMETER

PITCH

DIAMETER

BELT

HP

DIA.

SPEED

SHEAVE

SHEAVE

(QUANTITY)

(lb at

580G,H

DIAMETER

(in.)

DIAMETER

(in.)

LENGTH

 

(in.)

(rpm)

 

 

 

.24 in.)

 

 

 

(in.)

 

 

(in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

240

5

1.12

717

BK55

4.8

None-1.125

1B5V124

12.4

B-1.9375

BX59

62

5.10

10

1.38

924

2BK50

4.4

None-1.375

2B5V86

8.6

B-1.9375

(2) BX51

54

5.21

 

15

1.62

1096

2B5V56

5.7

B-1.625

2B5V90

9.1

B-1.9375

(2) 5VX530

53

6.00

300

7.5

1.38

773

BK60H

5.4

H-1.375

1B5V124

12.4

B-1.9375

BX59

62

6.48

10

1.38

962

1B5V60

6.1

H-1.375

1B5V110

11.1

B-1.9375

5VX590

59

7.37

 

15

1.62

1106

2B5V54

5.5

B-1.625

2B5V86

8.7

B-1.9375

(2) 5VX530

53

6.12

324

10

1.38

848

2BK50

4.4

None-1.375

2B5V94

9.4

B-1.9375

(2) BX52

55

5.27

15

1.62

1059

2B5V48

4.9

B-1.625

2B5V80

8.1

B-1.9375

(2) 5VX500

50

6.63

 

20

1.62

1187

2B5V58

5.9

B-1.625

2B5V86

8.7

B-1.9375

(2) 5VX530

53

7.31

360

10

1.38

884

2BK50

4.4

H-1.375

2B5V90

9.0

B-1.9375

(2) BX51

54

5.24

15

1.62

1096

2B5V56

5.7

B-1.625

2B5V90

9.1

B-1.9375

(2) 5VX530

53

6.00

 

20

1.62

1187

2B5V58

5.9

B-1.625

2B5V86

8.7

B-1.9375

(2) 5VX530

53

7.31

NOTE: Motor shaft speed is 1750 rpm. The fan shaft diameter is 111¤16 inches.

A. Positioning

Provide clearance around and above unit for air¯ow, safety, and service access (Fig. 2 and 3).

Do not install unit in an indoor location. Do not locate air inlets near exhaust vents or other sources of contaminated air.

For proper unit operation, adequate combustion and ventila- tion air must be provided in accordance with Section 5.3 (Air for Combustion and Ventilation) of the National Fuel Gas Code, ANSI Z223.1 (American National Standards Institute).

Although unit is weatherproof, guard against water from higher level runoff and overhangs.

B. Roof Mount

Check building codes for weight distribution requirements.

III. FIELD FABRICATE DUCTWORK

Secure all ducts to building structure. Use ¯exible duct con- nectors between unit and ducts as required. Insulate and weath- erproof all external ductwork, joints, and roof openings with counter ¯ashing and mastic in accordance with applicable codes.

Ducts passing through an unconditioned space must be insulated and covered with a vapor barrier.

To attach ductwork to roof curb, insert ductwork approx- imately 10 to 11 in. up into the curb. Connect ductwork to 14-gage roof curb material using sheet metal screws driven from inside the duct.

A. PositioningWARNING: For vertical supply and return units, tools or parts could drop into ductwork and cause an injury. Install 90 degree elbow turns in the supply and return ductwork between the unit and the conditioned space. If a 90 degree elbow cannot be installed, then grilles of sufficient strength and density should be installed to prevent objects from falling into the conditioned space.

IV. UNIT DUCT CONNECTIONS

A. 580G Units

Unit is shipped for through-the-bottom duct connections. Duct- work openings are shown in Fig. 2. Attach all ductwork to roof curb. Air distribution is shown in Fig. 5. Refer to installation instructions shipped with accessory roof curb for more information.

B. 580H Units

Remove shipping covers from supply and return air open- ings. Attach ®eld-supplied ductwork to unit. Use a single duct over both return openings and a single duct over both sup- ply openings. See Fig. 3 for duct opening dimensions. Secure all ducts to the building structure. See Fig. 6. Use ¯exible duct connectors between unit and ducts as required.

Install accessory barometric relief or power exhaust in the ®eld-fabricated return ductwork. Refer to Power Exhaust/Barometric Relief Damper Hood section for more information.

Fig. 5 Ð Air Distribution Ð Thru-the-Bottom

Fig. 6 Ð Air Distribution Ð Thru-the-Side

Ð7Ð

Page 7
Image 7
Bryant 580G manual Ð Evaporator Fan Motor Data, A. Positioning, B. Roof Mount, Iii. Field Fabricate Ductwork, B. 580H Units