HEAT PUMP
NO COOLING OR
INSUFFICIENT
COOLING
COMPRESSOR WILL NOT RUN
COMPRESSOR
RUNS BUT
CYCLES ON
INTERNAL
OVERLOAD
COMPRESSOR
RUNS BUT
INSUFFICIENT
COOLING
OUTDOOR FAN
HIGH SUCTION
HIGH SUCTION
CONTACTOR
OPEN
POWER SUPPLY
DEFECTIVE
OPEN
THERMOSTAT
OPEN CONTROL
CIRCUIT
LOSS OF
CHARGE
CONTACTOR OR COIL DEFECTIVE
LOOSE
CONTACTOR
CLOSED
COMPRESSOR POWER SUPPLY OPEN
LOOSE LEADS AT
COMPRESSOR
FAULTY START
GEAR
OPEN SHORTED OR GROUNDED COMPRESSOR MOTOR WINDINGS
COMPRESSOR
STUCK
COMPRESSOR
INTERNAL
PROTECTION
OPEN
STOPPED OR CYCLING ON OVERLOAD
OUTDOOR AIR
RESTRICTED OR RECIRCULATING
DAMAGED OR
STUCK
REVERSING
VALVE
RESTRICTED DISCHARGE TUBE
OVERCHARGE
OR NON-
CONDENSABLES
IN SYSTEM
LOW
REFRIGERANT
CHARGE
LINE VOLTAGE TOO HIGH OR LOW
LOOSE LEAD
AT FAN MOTOR
DEFROST RELAY N.C. CONTACTS OPEN
MOTOR
DEFECTIVE
INCORRECT
OFM
CAPACITOR
DEFECTIVE
DEFROST
THERMOSTAT
LOW SUCTION
PRESSURE
DIRTY AIR
FILTERS
DUCT
RESTRICTED
DAMPERS
PARTLY CLOSED
INDOOR COIL
FROSTED
SLIGHTLY
LOW ON
REFRIGERANT
LIQUID LINE
SLIGHTLY
RESTRICTED
LOW HEAD
PRESSURE
REVERSING
VALVE HUNG UP
OR INTERNAL
LEAK
DEFECTIVE
COMPRESSOR
VALVES
INTERNAL
PRESSURE
RELIEF OPEN
LOW
SUPERHEAT
UNIT
OVERCHARGED
INCORRECT
SIZE
PISTON
ELECTRICAL CONNECTION
DEFECTIVE RUN
CAPACITOR
DEFECTIVE RUN
CAPACITOR
COMPRESSOR
BEARINGS
HIGH
SUPERHEAT
PISTON
RESTRICTED
INCORRECT
SIZE
PISTON
INDOOR COIL
STRAINER
RESTRICTED
INDOOR
BLOWER MOTOR
DEFECTIVE OR CYCLING ON OL
A90207