Chapter 4 Web Admin interface

Name

Storage

Descriptions

 

Configure RAID arrays from this menu. RAID 0 and RAID 1 modes are available.

 

If RAID is disabled, the drives in the LinkStation will be available as separate

 

drives.

 

 

 

[Disk Structure]:

 

 

 

To configure a RAID array, check the target drives, select a RAID mode, and

 

click [Create Raid Array]. To delete the RAID array, select [Delete RAID Array].

 

Warning: All data is lost when the RAID array is modified. Back up any

RAID Array *1

 

important data before changing RAID settings.

 

 

 

 

 

*1: LinkStation models with

[RAID Array Error Detection Response]:

If shutdown is enabled, the LinkStation will automatically shut down when

multiple hard drives only

a RAID 1 error is detected. RAID 0 arrays and drives in normal mode are not

 

 

affected by this setting.

 

 

 

The default setting is [Shutdown].

 

[RAID Array check speed]:

 

 

 

Select the RAID scanning speed from the following:

 

[High]: ~ 10 hours per TB

 

 

 

[Normal]: ~ 20 hours per TB

 

[Low]: ~ 100 hours per TB

 

 

 

 

 

 

 

 

A RAID scan tests your RAID array for errors. If errors are found, they are fixed

 

automatically if possible. If you are using a RAID array, regular RAID scans are

 

recommended.

 

 

 

Recoverable errors found during standard file operations will be automatically

RAID Scanning *1

repaired regardless of whether RAID Scanning is enabled or not.

 

 

 

 

 

 

*1: LinkStation models with

 

Status

 

Examples

 

multiple hard drives only

 

Recoverable errors

 

Read errors in data or system area of a RAID 1

 

 

 

 

 

array

 

 

 

Unrecoverable errors

 

Write errors, RAID management area errors,

 

 

 

 

 

partition errors, drive detection failure

 

 

 

 

 

 

 

LinkStation User Manual

136

Page 137
Image 137
Buffalo Technology LSV40TL Drives Disk Structure, Affected by this setting Default setting is Shutdown, Recommended