Chapter 4 Web Admin interface

Name

Storage

Descriptions

Backup

If many recoverable errors (bad cluster) are found in one of the hard drives which builds RAID, that drive will be removed and the system will automatically move to degrade mode.

Since the data is not protected in the degrade mode, it is strongly recommended to replace the erroneous hard drive immediately.

When running RAID Scanning in the first time, it is strongly recommended to backup data on the LinkStation in advance.

[RAID Scanning]:

Set whether using RAID Scanning or not.

[RAID Scanning Schedule]:

Select the schedule to perform RAID Scanning.

[Every Week], select from [Sunday] to [Saturday]

[1st], from [Sunday] to [Saturday]

[2nd], from [Sunday] to [Saturday]

[3rd], from [Sunday] to [Saturday]

[4th], from [Sunday] to [Saturday]

[1st, 3rd], from [Sunday] to [Saturday]

[2nd, 4th], from [Sunday] to [Saturday]

[Every 1st day / month]

Select [Begin Immediate RAID Scan]] and click [Save] to immediately run the maintenance.

[RAID Scanning Start Time]:

Select time to start RAID from 0 to 23 o’clock. *Click [Abort RAID Scanning] to stop the operation.

View NAS Devices

Local

Displays LinkStations and TeraStations on the network with shares enabled for

LinkStations

backup.

 

Click [Refresh] to update the list.

Off Subnet

You can add an off-subnet LinkStation or TeraStation to the list. Enter the IP

LinkStations

address of the LinkStation/TeraStation and click [Add].

 

Note: Only devices with active backup shares can be registered.

 

 