Chapter 4 Web Admin interface

Name

 

Descriptions

 

 

 

Maintenance

 

 

 

 

 

 

Notification

Select whether using E-mail notification feature or not. Following

 

 

message is sent by using E-mail Notification.

 

 

Note: Mail Server displays the list of [POP before SMTP] (the method to

 

 

give the permission to use SMTP server by authenticating at specified

 

 

POP server before sending e-mail). If this is set, this feature cannot be

 

 

used.

 

SMTP Server

Enter [SMTP Server Address] (Mail Server Address).

 

Address

 

 

SMTP Port No.

Enter [SMTP Port No.].

 

Authentication Type

Select [Authentication Type] from [POP before SMTP], [LOGIN(SMTP-

Email

 

AUTH)], and [CRAM-MD5(SMTP-AUTH/CRAM-MD5)].

 

 

Notification

 

 

POP3 Server

Enter the [POP3 Server Address] (E-mail server address).

Click [Modify

Address

 

Settings]

 

 

POP3 Port No.

Enter [POP Port No.].

to change

SSL/TLS

When [LOGIN(SMTP-AUTH)] and [CRAM-MD5(SMTP-AUTH/CRAM-

settings.

 

MD5)] are selected for [Authentication Type], specify either using [SSL]

 

 

or [TLS].

Click [Send

Username

Enter a user name that will be used for authentication.

Test Message]

 

 

Password

Enter the password used to access with above user name.

to send a test

Subject

Specify the subject of the e-mail to be sent. Use only one-byte

e-mail to the

 

characters, not two-byte characters.

e-mail address

Recipient(s)

Enter the e-mail address of the receiver, and click [Add]. You can

which has

 

register up to 5 e-mail addresses as receivers.

been set.

Report

Select the contents to send in the e-mail notification.

 

 

• [HDD Status Report]

 

 

Send the status other hard drive of the LinkStation on the specified

 

 

time on [HDD Status Sending Time].

 

 

• [Fan Failure]

 

 

Sent if a problem on the fan of the LinkStation.

 

 

• [Disk Error]

 

 

Sent when an error occurs on the drive.

 

 

• [Backup Complete]

 

 

When the backup job is completed

 

 

Sent if the backup of the LinkStation is completed.

Maintenance

 

 

Restart

Restart the

Click [Restart] to reboot the LinkStation.

LinkStation