Bunn FMD-1 FMD-2 SERVICE cont, CONTROL BOARD - FMD-2 ONLY CONT, Dispense Switch, Location

Models: FMD-1 FMD-2

1 41
Download 41 pages 26.34 Kb
Page 22
Image 22
FMD-1

SERVICE (cont.)

CONTROL BOARD - FMD-2 ONLY (CONT.)

7.Check the voltage across the red (+) terminal and the black (-) terminal of the auger motor with a voltmeter. Connect the dispenser to the power source. Press and hold the appropriate dispense switch. After a delay of about .6 seconds, the indication must be between +4.0 and +24.5 volts dc.

If the voltage is present as described, the hopper motor control circuitry is operating properly.

If the voltage is not present as described, replace the control circuit board.

Removal and Replacement:

1.Disconnect the three plugs on the main wiring harness from the connectors on the control board.

2.Remove the four #6-32 keps nuts securing the control board to the component bracket.

3.Remove control board and discard.

4.Install new control board on the component bracket using four #6-32 keps nuts.

5.Reconnect the three plugs on the main harness to the connectors on the control board.

J2

J3

 

 

J2

 

 

 

J3

 

 

J4

J1

 

 

J1

J4

 

 

P1640

FIG. 13 CONTROL BOARD CONNECTORS

DISPENSE SWITCH(S) - FMD-1 & FMD-2

 

 

 

 

CUP

 

 

 

N U

NTIL

 

 

 

BUTTORELEASE

 

 

 

HOLD THEN

 

 

 

 

and FULL,

 

 

 

PUSHIS

2/3

 

 

 

FULL

 

 

 

 

IS 2/3

 

 

 

 

CUP

 

 

 

 

WHEN

 

 

 

ASE

PLACE

 

 

 

RELE

 

 

 

 

HERE

 

 

 

 

CUP

 

 

 

 

 

 

FMD-1

 

 

 

 

CUP

 

 

 

UNTIL

 

 

 

BUTTONRELEASE

 

 

 

and FULL,

 

 

 

PUSHIS

2/3

 

 

 

FULL

 

 

 

 

IS 2/3

 

 

 

 

CUP

 

 

 

 

WHEN

 

 

 

RELEASE

PLACE

 

 

 

HERE

 

 

 

 

CUP

 

 

 

PLACE

 

 

 

 

HERE

 

 

 

 

CUP

 

 

 

 

 

 

 

FMD-2

 

FIG.14 DISPENSE SWITCH

P1614

 

Location:

 

 

 

 

The dispense switch(es) is (are) located on the lower outside of the dispenser door.

22

29112 101598

 

Page 22
Image 22
Bunn FMD-1 FMD-2 service manual SERVICE cont, CONTROL BOARD - FMD-2 ONLY CONT, Dispense Switch, Location