SERVICE (cont.)
LIMIT THERMOSTAT
|
|
|
| 1 |
|
|
| L2 | LT |
| L4 | L3 | T |
|
5 | T |
|
| |
TL | T |
|
|
|
Removal and Replacement
1.Remove all wires from the limit thermostat termi- nals.
2.Carefully remove the two
3.Carefully secure new limit thermostat to tank lid.
4.Refer to Fig. 18 when reconnecting the wires.
BLK to Terminal Block |
|
|
| BLK to Tank Heater |
(Black Insert) |
|
|
| |
|
|
|
|
|
|
|
|
|
|
FIG. 17 LIMIT THERMOSTAT | P2231.35 |
| |
| |
|
|
Location:
The limit thermostat is located inside the hood on the tank lid to the left of the tank heater.
Test Procedure:
1.Disconnect the brewer from the power supply.
2.Disconnect both black wires from the limit ther- mostat.
3.With an ohmmeter, check for continuity across the limit thermostat terminals.
If continuity is present as described, reconnect the black wires to the limit thermostat , the limit thermo- stat is operating properly.
If continuity is not present as described, press the reset button on the limit thermostat and repeat step #3.
After repeating step #3 and no continuity is shown, replace the limit thermostat.
FIG. 18 LIMIT THERMOSTAT TERMINALS