Bunn System III manual SERVICE cont START SWITCH

Models: System III

1 40
Download 40 pages 46.35 Kb
Page 32
Image 32
SERVICE (cont.)

SERVICE (cont.)

START SWITCH

FIG. 25 START SWITCH

P1104

 

Location:

The start switch is located in front of hood to the left of the ON/OFF switch.

Test Procedure:

1.Disconnect the brewer from the power source and remove the wires from both terminals of the switch.

2.Check for continuity across the two terminals on the switch when it is held in the lower position. Continuity must not be present across these ter- minals in the upper position.

If continuity is present as described, reconnect the wires, the switch is operating properly.

If continuity is not present as described, replace the switch.

Removal and Replacement:

1.Remove all wires from the switch terminals.

2.Compress the clips inside the hood and gently push the switch through the opening.

3.Push the new switch into the opening and spread the clips to hold the switch in the hood.

4.Refer to FIG. 26 when reconnecting the wires.

WHI/ORN to Timer TL3 - (Electro/Mechanical) or BLK to DBC J3-6

WHI/YEL to Timer TL5 - (Electro/Mechanical) or BLU to DBC J3-21

FIG. 26 START SWITCH TERMINALS

P1108

 

 

 

Page 32

27362

092900

 

 

Page 32
Image 32
Bunn System III manual SERVICE cont START SWITCH