Bunn System III manual TROUBLESHOOTING cont, Problem, Probable Cause, Remedy

Models: System III

1 40
Download 40 pages 46.35 Kb
Page 9
Image 9

TROUBLESHOOTING (cont.)

 

 

 

Problem

Probable Cause

Remedy

Automatic refill will not operate

6.

Solenoid Valve

Refer to Service - Solenoid valve for

(cont.)

 

 

testing procedures. See page 30

Beverage level will not adjust (Selec-

1.

Selector switch

Refer to Service - Selector switch for

tor switch in any position)

 

 

testing procedures. See page 16

Water flows into tank continuously

1. (A) Level control board and level

Refer to Service - Level control board

(ON/OFF Switch "OFF")

probe (Electro/mechanical)

for testing procedures. See page 25

 

 

(B) Digital Brewer Control

Refer to Service - Digital brewer

 

 

 

control for testing procedures. See

 

 

 

page 23 step 10

 

2.

Overflow protection switch

Refer to Service - Overflow protec-

 

 

 

tion switch for testing procedures.

 

 

 

See page 29

 

3.

Solenoid valve

Refer to Service - Solenoid valve for

 

 

 

testing procedures. See page 30

Water from tank is not hot

1.

Limit thermostat

Refer to Service -Limit thermostat

 

CAUTION - Do not eliminate or by-

for testing procedures. See page 27

 

pass limit thermostat. Use only

 

 

B.O.M. part #23717.0001

 

2.(A) Control Thermostat (Electro/ mechanical)

(B)Digital Brewer Control

Refer to Service - Control thermo- stat for testing procedures. See page 20

Refer to Service - Digital brewer control for testing procedure. See page 22 step 3

3.

Contactor (Electro/mechanical)

Refer to Service - Contactor for test

 

 

procedures. See page 18

4.

Tank heater

Refer to Service - Tank heater for

 

 

testing procedures. See page 33

Page 9

27362

092900

 

 

Page 9
Image 9