SERVICE (cont.) |
|
|
| |
WARMER ELEMENT |
| 4. | Disconnect wires from the warmer element. | |
|
| |||
|
| 5. | Check the continuity across the two terminals on | |
|
|
| the warmer element. | |
|
| If continuity is present as described, reconnect the | ||
|
| white or red wire and white/red wires, or the white or | ||
|
| red wire and white/violet wires on the warmer element. | ||
|
| If continuity is not present as described, replace the | ||
|
| warmer element. | ||
|
| Removal and Replacement: | ||
|
| 1. | Remove the four | |
|
|
| (warmer) plate to the brewer housing. | |
|
| 2. | Turn base plate over and disconnect the two wires | |
|
|
| from the warmer element. | |
|
| 3. | Remove the | |
|
|
| and warmer element. Discard warmer element. | |
|
| 4. | Place new warmer element on the center bottom | |
|
|
| of the base plate with the warmer terminals point- | |
|
|
| ing up and to the rear of the base plate. | |
|
| 5. | Install warmer retainer plate and warmer element | |
FIG. 33 WARMER ELEMENT | P1111.35 |
| over the stud in bottom of the base plate, secure | |
| with | |||
|
| |||
Location: |
| 6. | Reconnect the two wires to warmer element termi- | |
|
| nals. | ||
The warmer element is located on the bottom the |
| |||
7. | Turn base plate over and reinstall with four | |||
base (warmer) plate. |
| |||
|
| screws to the brewer housing. | ||
|
|
| ||
Test Procedures: |
| 8. | Refer to Fig. 34 when reconnecting wires. | |
|
|
|
1.Disconnect the brewer from the power source.
2.On 120/208V or 120/240V models, with a voltme- ter, check the voltage across the white wire and the white/violet wire or white/red wire to the ele-
ment with the "ON/OFF (Warmer)" switch in the |
|
|
|
| WHI/VIO to ON/OFF Switch (Electro/Mechanical) | |||
"ON" (upper) position. On 200V or 240V models, |
|
|
|
| ||||
with a voltmeter, check the voltage across the red |
|
|
|
| WHI/RED to ON/OFF Switch (DBC) | |||
|
|
|
| |||||
|
|
|
|
|
|
|
| |
wire and the white/violet wire or white/red wire |
|
|
|
|
|
|
|
|
with the "ON/OFF (Warmer)" switch in the "ON" |
|
|
|
|
|
| WHI to Terminal Block (120/208V or 120/ | |
(upper) position. The indication must be: |
|
|
|
|
|
| 240V Brewers) | |
|
|
|
|
| ||||
a.)120 volts ac for three wire 120/208 volt models |
|
|
|
|
|
| RED to Terminal Block (200V or 240V | |
|
|
|
|
|
| Brewers | ||
and three wire 120/240 volt models. |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
| |
b.) 200 to 240 volts ac for two wire 200 or 240 volt |
|
|
|
|
|
|
|
|
models. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
3. Disconnect the brewer from the power source. |
|
|
|
|
|
|
|
|
If voltage is present as described, proceed to #4.
P1110
If voltage is not present as described, refer to theFIG. 34 WARMER ELEMENT TERMINALS Wiring Diagrams and check brewer wiring harness.
Page 37 | 27362 | 092996 |
|
|