Bunn System III manual Warmer Element, SERVICE cont

Models: System III

1 40
Download 40 pages 46.35 Kb
Page 37
Image 37
WARMER ELEMENT

SERVICE (cont.)

 

 

 

WARMER ELEMENT

 

4.

Disconnect wires from the warmer element.

 

 

 

 

5.

Check the continuity across the two terminals on

 

 

 

the warmer element.

 

 

If continuity is present as described, reconnect the

 

 

white or red wire and white/red wires, or the white or

 

 

red wire and white/violet wires on the warmer element.

 

 

If continuity is not present as described, replace the

 

 

warmer element.

 

 

Removal and Replacement:

 

 

1.

Remove the four #6-32 screws securing the base

 

 

 

(warmer) plate to the brewer housing.

 

 

2.

Turn base plate over and disconnect the two wires

 

 

 

from the warmer element.

 

 

3.

Remove the #8-32 Keps nut, warmer retainer plate

 

 

 

and warmer element. Discard warmer element.

 

 

4.

Place new warmer element on the center bottom

 

 

 

of the base plate with the warmer terminals point-

 

 

 

ing up and to the rear of the base plate.

 

 

5.

Install warmer retainer plate and warmer element

FIG. 33 WARMER ELEMENT

P1111.35

 

over the stud in bottom of the base plate, secure

 

with #8-32 Keps nut.

 

 

Location:

 

6.

Reconnect the two wires to warmer element termi-

 

 

nals.

The warmer element is located on the bottom the

 

7.

Turn base plate over and reinstall with four #6-32

base (warmer) plate.

 

 

 

screws to the brewer housing.

 

 

 

Test Procedures:

 

8.

Refer to Fig. 34 when reconnecting wires.

 

 

 

1.Disconnect the brewer from the power source.

2.On 120/208V or 120/240V models, with a voltme- ter, check the voltage across the white wire and the white/violet wire or white/red wire to the ele-

ment with the "ON/OFF (Warmer)" switch in the

 

 

 

 

WHI/VIO to ON/OFF Switch (Electro/Mechanical)

"ON" (upper) position. On 200V or 240V models,

 

 

 

 

with a voltmeter, check the voltage across the red

 

 

 

 

WHI/RED to ON/OFF Switch (DBC)

 

 

 

 

 

 

 

 

 

 

 

 

wire and the white/violet wire or white/red wire

 

 

 

 

 

 

 

 

with the "ON/OFF (Warmer)" switch in the "ON"

 

 

 

 

 

 

WHI to Terminal Block (120/208V or 120/

(upper) position. The indication must be:

 

 

 

 

 

 

240V Brewers)

 

 

 

 

 

a.)120 volts ac for three wire 120/208 volt models

 

 

 

 

 

 

RED to Terminal Block (200V or 240V

 

 

 

 

 

 

Brewers

and three wire 120/240 volt models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

b.) 200 to 240 volts ac for two wire 200 or 240 volt

 

 

 

 

 

 

 

 

models.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. Disconnect the brewer from the power source.

 

 

 

 

 

 

 

 

If voltage is present as described, proceed to #4.

P1110

If voltage is not present as described, refer to theFIG. 34 WARMER ELEMENT TERMINALS Wiring Diagrams and check brewer wiring harness.