Bunn System III manual TROUBLESHOOTING cont Problem, Probable Cause, Remedy

Models: System III

1 40
Download 40 pages 46.35 Kb
Page 8
Image 8

TROUBLESHOOTING (cont.)

Problem

Brew cycle will not start (cont.)

Probable Cause

3.ON/OFF switch

4.Start switch

5.Timer

6.Dispense Valve

7.Digital Brewer Control

Remedy

Refer to Service - ON/OFF switch for testing procedures. See page 28

Refer to Service - Start switch for testing procedures. See page 32

Refer to Service - Timer for testing procedures. See page 34 or 35

Refer to Service - Dispense valve for testing procedures. See page 21

Refer to Service - Digital brewer controls for testing procedures. See page 22 step 4

Automatic refill will not operate

1.No water

2.Water strainer/flow control (.500 GPM)

Check plumbing and shut-off valves.

(A)Direction of flow arrow must be pointing towards the right.

(B)Remove the strainer/flow con- trol and check for obstructions. Clear or replace.

3.Limit thermostat (Electro/me- chanical and Digital Brewer Control)

4.Overflow protection switch

Refer to Service - Limit thermostat for testing procedures. See page 27

Refer to Service - Overflow protec- tion switch for testing procedures. See page 29

5.(A) Level control board & level probe. (Electro/mechanical)

(B)Digital Brewer Control Assem- bly (DBC)

Refer to Service - Level control board for testing procedures. See page 25

Refer to Service - Digital brewer control for testing procedures. See page 22 step 2