7.Tighten the screws on each side of the switch module’s front panel.

Swapping a Switch Module

6.Gently slide the new switch module into the plastic guides in the module slot until it is completely inserted. Push the module firmly into place, as far as it will go, to fully engage the connectors at the back of the module with the backplane at the rear of the ATX chassis.

7.Tighten the screws on each side of the switch module’s front panel.

8.If you took the original module offlline by pressing the OFFLINE button, the new switch module will automatically come back online when it is inserted in the slot.

If you used the Local Console Manager offline command to take the original module offline, you must use the online command to bring the new module online.

9.Check the switch module LED power-on sequence as described in Chapter 2, Connecting to the Network.

10.Make the connections to the network as described in Chapter 2.