Using the Console

Switch Installation and Setup

2p›F When you accept the (all) default for show, the information displayed is often abridged.

2.5.2Console Time-out

The console can be configured to exit if it does not sense a key stroke within a defined length of time. By default, the SmartCell 6A000 is set to never time-out (value = 0). To activate the time-out feature, use the set ConsoleTimeOut command to adjust the time-out period:

SmartCell ZX # set consoletimeout

Timeout(0)

: 30 <Will time-out in 30 minutes without input

Confirm (y/N)? : y

SmartCell ZX #

2.5.3Creating an Alias

Use the add alias command to create shorter or easier-to-remember names for command lines. For example:

SmartCell

ZX # add alias

 

AliasName()

: traffic

AliasedString()

: set switchtrafficcongestion

SmartCell

ZX #

 

The above example creates an alias (traffic) that can be entered in place of the command set

SwitchTrafficCongestion. For example:

SmartCell ZX # traffic

Queue1EFCIThreshold(4096):

Queue2EFCIThreshold(4096):

Queue3EFCIThreshold(4096):

Queue4EFCIThreshold(4096):

LowEPDWatermark(10922):

HighEPDWatermark(21845):

RMCellMarkingEnable(1):

EFCIMarkingEnable(1):

SmartCell ZX #

Enter the show alias command to display a list of all defined aliases and the command lines to which they correspond.

:SmartCell

ZX # show alias

 

AliasName(ALL)

:

Alias List

 

 

==============================================================================

Index

Alias

Name

: Aliased Command

1

PING

 

: Start ping

2

xxx

 

: show portconfig

3

traffic

: set switchtrafficcongestion

SmartCell ZX

#

 

2-10 SmartCell 6A000 User Guide