Configuring the Switch

Switch Installation and Setup

¢• Configure dumb terminals or PCs running emulation software with the following communication parameters:

UBaud rate = 9600

UData bits = 8

UStop bits = 1

UFlow control = none

••Plug one end of the supplied RJ-45 UTP cable into the 9-pin RJ-45 adapter (see Figure 2-3)

2p›F For information about adapter wiring configurations, see Appendix A, "Specifications."

T• Plug the other end of the UTP cable into the SmartCell 6A000 female RJ-45 jack labeled Terminal, located on the front panel (see Figure 2-3).

Q• Connect the switch to your network by plugging a UTP cable into the SmartCell 6A000 female RJ-45 jack labeled Ethernet, located near the center of the switch's front panel (see Figure 2-3).