Switch Administration

TrafficManagement

For example, enter the show porttrafficcongestion command to view current buffer utilization.

SmartCell ZX # show porttrafficcongestion

 

 

 

PortNumber(ALL)

 

 

 

 

:

 

 

Port ID

Queue 1

Queue 2

Queue 3

Queue 4

 

Min

Max

Min

Max

Min

Max

Min

Max

============================================================================

A1

20

1000

20

2000

20

1000

20

16384

A2

20

1000

20

2000

20

1000

20

16384

A3

20

1000

20

2000

20

1000

20

16384

A4

20

1000

20

2000

20

1000

20

16384

B1

20

1000

20

2000

20

1000

20

16384

B2

20

1000

20

2000

20

1000

20

16384

B3

20

1000

20

2000

20

1000

20

16384

B4(CPU)

20

1000

20

2000

20

1000

20

16384

C1

20

1000

20

2000

20

1000

20

16384

C2

20

1000

20

2000

20

1000

20

16384

C3

20

1000

20

2000

20

1000

20

16384

C4

20

1000

20

2000

20

1000

20

16384

D1

20

1000

20

2000

20

1000

20

16384

D2

20

1000

20

2000

20

1000

20

16384

D3

20

1000

20

2000

20

1000

20

16384

D4

20

1000

20

2000

20

1000

20

16384

SmartCell ZX #

 

 

 

 

 

 

 

 

Min and Max are thresholds set on a per-queue, per-port basis and are measured in cells (53 bytes). The Min threshold is the amount of buffer space guaranteed to a call of a particular QoS on the corresponding port. The Max threshold is the maximum amount of buffer space that a call of a particular QoS is allowed on the corresponding port.

QoS corresponds to the queues as follows:

Queue 1 — Constant Bit Rate (CBR)

Queue 2 — Real Time Variable Bit Rate (rt-VBR)

Queue 3 — Non-real time Variable Bit Rate (Nrt-VBR)

Queue 4 — Unspecified Bit Rate (UBR)

If calls of a particular QoS type are being dropped on a particular port, use the set porttrafficcongestion command to raise the port’s queue Min threshold.

For example, to change both the Min and Max amounts of buffer space used for CBR calls on port a3, enter the following:

SmartCell ZX # set porttrafficcongestion

 

Port(ALL)

: a3

Queue1MinimumCellCounter(20)

: 1000 < Min for CBR queue

Queue2MinimumCellCounter(20)

:

Queue3MinimumCellCounter(20)

:

Queue4MinimumCellCounter(20)

:

Queue1MaximumCellCounter(1000)

: 10000 < Max for CBR queue

Queue2MaximumCellCounter(2000)

:

Queue3MaximumCellCounter(1000)

:

Queue4MaximumCellCounter(16384)

:

SmartCell ZX #

 

SmartCell 6A000 User Guide 4-21

Page 63
Image 63
Cabletron Systems 6A000 manual Min for CBR queue