Switch Installation and SetupInstalling the Switch

Table 2-1 I/O module ID numbers (Continued)

Face Plate Number

Physical Specification

 

 

 

6A-IOM-29-4-LR

155

Mbps OC-3/STS-1, SMF-LR/SC (4 port)

 

 

6A-IOM-31-1

622 Mbps OC-12/STM-4, MMF/SC (1 port)

 

 

 

6A-IOM-39-1

622

Mbps OC-12/STM-4, SMF-IR/SC (1 port)

 

 

 

6A-IOM-39-1-LR

622

Mbps OC-12/STM-4, SMF-LR/SC (1 port)

 

 

6A-IOM-67-4

45 Mbps DS-3, Coax/BNC (4 port)

 

 

6A-IOM-77-4

34 Mbps E-3, Coax/BNC (4 port)

 

 

 

If the hardware configuration is incorrect, contact Cabletron customer support immediately.

2.2.1DS3 and E3 I/O Module Configuration

Table 2-2shows the pre-configured values for both the DS3 (6A-IOM-67-4) and E3 (6A-IOM-77-4) I/O modules. These values cannot be changed. Accordingly, configure the connecting device’s interface to use these values.

Table 2-2 DS3 and E3 Module settings

Protocol

Mode

Framing

Empty Cell

Timing

Scrambling

Length

 

 

 

 

 

 

 

DS3

plcp

cbit

unassigned

internal

off

greater than 225 ft.

 

 

 

 

 

 

 

E3

plcp

G.751

unassigned

internal

off

N/A

 

 

 

 

 

 

 

2.3INSTALLING THE SWITCH

The SmartCell 6A000 is hot swappable, meaning that you can install and remove it without turning off or unplugging the SmartSwitch 6000 chassis. You can install as many as five switch modules in each chassis (using the 6C205-3 power supply). In this configuration, the SmartCell 6A000 modules provide up to 75 user ports. Modules should be connected with inter-module trunks if traffic must cross between modules. Table 2-3shows the maximum number of LAN and ATM switch modules that can be installed in a SmartSwitch 6000 chassis.

Table 2-3 SmartSwitch 6000 contents

Number of 6Exxx or 6Hxxx modules installed

0

1

2

3

4

5

 

 

 

 

 

 

 

Number of 6A000 modules that can be added

5

4

3

2

1

0

 

 

 

 

 

 

 

SmartCell 6A000 User Guide 2-3

Page 21
Image 21
Cabletron Systems 6A000 manual Installing the Switch, 1 DS3 and E3 I/O Module Configuration