Soldadora Por Arco Con Alimentación de Cable Modelos WG2060 y WG2064
Models WG2060 and WG2064
Para Ordenar Repuestos o Asistencia Técnica, Sírvase Llamar al Distribuidor Más Cercano a Su Domicilio
Sírvase suministrarnos la siguiente información:
-Número del modelo
-Número de Serie (de haberlo)
-Descripción y número del repuesto según la lista de repuestos
Dirija toda la correspondencia a:
Campbell Hausfeld
Attn: Customer Service
100 Mundy Memorial Drive
Mt. Juliet, TN 37122 U.S.A.
|
| 12 |
|
|
|
|
| 6 | 1 |
|
|
|
|
| 2 | 3 | |
|
|
|
| ||
|
| 5 |
|
| |
|
|
|
|
| |
|
|
|
| 4 |
|
11 |
|
|
|
|
|
10 |
|
|
|
|
|
9 | 8 | 7 |
|
|
|
|
|
|
| ||
|
|
|
|
| |
Figura 14 - Piezas de Repuesto |
|
|
|
Assembly (Continued)
Torch Diffuser
Contact Tip
Nozzle
Figure 4 - Torch Nozzle
Contact Tip Markings
Mark | Wire Size |
|
|
0.6 mm | .024" |
|
|
0.8 mm | .030” |
|
|
0.9 mm | .035” |
|
|
|
|
POLARITY
MIG welding wire requires electrode
2.Remove cover screw and polarity cover.
3.Remove four nuts from polarity studs.
4.Pull out polarity bus bar and rotate it 90°. Reinsert aligning groove with the correct rib in polarity box.
Upper right rib marks the MIG position; lower right rib marks the Flux position. (See Figure 4c.)
Upper right— | Lower right— |
MIG rib | Flux rib |
Shielding Gas Preparation
Improper handling
! DANGER and maintenance of compressed gas cylinders and regulators can result in serious injury or death!
Always secure gas cylinders to tank bracket kit, a wall or other fixed support to prevent cylinder from falling over. Read, understand and follow all compressed gas and equipment warnings in the safety instructions.
NOTE: Shielding gas is not required if
GAS TYPES
There are 3 types of gas generally used for gas metal arc welding; 100% argon, a mixture of 75% argon and 25% carbon dioxide (C25) or 100% carbon dioxide.
No de | No De |
| |
Ref. Descripción | Componente Cant | ||
1 | Ensamble del soplete y la manguera |
|
|
| (MIG, 2,44 m, WG2060) | WC403660AV 1 | |
| Ensamble del soplete y la manguera |
|
|
| (MIG, 3,05 m, WG2064) | WC404100AV 1 | |
2 | Punta de contacto - 0,035” (0,9 mm) | WT501400AV 1 | |
| Punta de contacto opcional – 0,024” |
|
|
| (0,6 mm) Paq. 4 | WT501200AJ | † |
| Punta de contacto opcional – 0,030” |
|
|
| (0,8 mm) Paq. 4 | WT501300AJ | † |
| Punta de contacto opcional – 0,035” |
|
|
| (0,9 mm) Paq. 4 | WT501400AJ | † |
3 | Boquilla | WT502100AV 1 |
No de | No De |
Ref. Descripción | Componente Cant |
Alambre de soldar MIG – 0,030” (0,8 mm) |
|
Bobina de 2 lb. (0,9 kg) (ER70S6) | WE300501AV † |
Alambre de soldar MIG – 0,030” (0,8 mm) |
|
Bobina de 11 lb. (5 kg) (ER70S6) | WE302000AV † |
Alambre de soldar MIG – 0,035” (0,9 mm) |
|
Bobina de 2 lb. (0,9 kg) (ER70S6) | WE301001AV † |
Alambre de soldar MIG – 0,035” (0,9 mm) |
|
Bobina de 11 lb. (5 kg) (ER70S6) | WE302500AV † |
Alambre de soldar MIG – 0,030” (0,8 mm) |
|
1 lb (0,45 kg) de aluminio (ER5356) | WE303001AV † |
11 Retén del recipiente con 4 tornillos | WC302600AJ 1 |
12 Conexión dentada de la manguera |
|
positive electrical polarity. Flux welding wire requires electrode negative electrical polarity. The welder is factory set for flux welding wire.
To Change Polarity (See Figure 4b)
NOTE: The arrow on the Polarity Cover points to the current polarity setting. TOOLS NEEDED: Phillips screwdriver and 10mm socket wrench.
1. Unplug power cord from socket.
MIG position | Flux position |
Figure 4c
5.Reinstall four nuts and tighten securely.
6.Reinstall polarity cover and cover screw.
7.Make sure arrow on polarity cover points to desired setting.
Use ONLY the type of gas recommended
for your welder. Use ONLY an inert, non- flammable type of gas. Failure to do so will result in a very hazardous situation.
NOTE: 100% carbon dioxide is not recommended due to unsatisfactory weld beads.
The 75/25 mixture is recommended for general steel welding. For aluminum welding, use 100% argon. Cylinders of either type gas may be obtained at your local welding supply outlet. Secure cylinder in place on your welding machine or other support to prevent the cylinder from falling over.
4 | Portabobinas | WC500805AV 1 |
5 | Ensamble de la placa de conducción | WC500800AJ 1 |
6 | Vástago y rejilla | WC707018AV 1 |
7 | Retén de la bobina | WC707024AV 1 |
8 | Resorte del retén de la bobina | WC707026AV 1 |
9 | Anillo del retén de la bobina | WC707023AV 1 |
10 | Alambre de soldar con fundente – 0,030” |
|
| (0,8 mm) Bobina de 2 lb. (0,9 kg) | WE200001AV † |
| Alambre de soldar con fundente – 0,030” |
|
| (0,8 mm) Bobina de 10 lb. (4,54 kg) | WE201000AV † |
| Alambre de soldar con fundente – 0,035” |
|
| (0,9 mm) Bobina de 2 lb. (0,9 kg) | WE200501AV † |
| Alambre de soldar con fundente – 0,035” |
|
| (0,9 mm) Bobina de 10 lb. (4,54 kg) | WE201500AV † |
| Alambre de soldar MIG – 0,024” |
|
| (0,6 mm) Bobina de 2 lb (0,9 kg) (ER70S6) | WE300001AV † |
| Alambre de soldar MIG – 0,024” |
|
| (0,6 mm) Bobina de 11 lb. (5 kg) (ER70S6) | WE301500AV † |
|
| (externa) | WC403900AV 1 | |
|
| ▲ Accesorio de conexión rápida |
|
|
|
| (interna) | WC403901AV 1 | |
| 13 | ▲ Manguera de gas – 22” (56 cm) | WC403902AV 1 | |
14 | ▲ Abrazadera de la manguera | WC403903AV 2 | ||
15 | ▲ Regulador (WG2060) | WC803500AV 1 | ||
|
| ▲ Regulador (WG2064) | WC803600AV 1 | |
| 16 | ▲ Máscara de mano |
|
|
|
| (no se incluyen lentes) | WC801700AV 1 | |
17 | ▲ Lentes oscuros |
|
| |
|
| (para máscara de mano) | WC801100AV 1 | |
18 | ▲ Martillo/cepillo cincelador | WC803400AV 1 | ||
19 | ▲ Etiqueta adhesiva de seguridad | DK688509AV | 1 | |
20 | ▲ Juego de la barra de polaridad | WC403128AV 1 | ||
21 ▲ Pinza de tierra (WG2060) | WC100300AV | 1 | ||
|
| ▲ Pinza de tierra (WG2064) | WC100600AV | 1 |
| 22 | ▲ Guantes para soldar (sólo WG2064) | WT200501AV | 1 |
▲ No se muestra |
|
| ||
| † | Accesorio opcional |
|
|
MIG rib
Polarity box | Polarity studs |
Groove
Nuts
Polarity cover
Flux rib
Polarity bus bar
Cover screw
Figure 4b
Obtaining Correct Gas Type. The gas used in any welding application for your welder must be an INERT, NON- FLAMMABLE TYPE. You can get the type of gas needed from a nearby welding gas distributor (often found in the yellow pages under “Welders” or ‘Welding Equipment”).
REGULATOR
An adjustable regulator without gauges is supplied with the WG2060. The regulator supplied with the WG2064 includes two gauges. The regulator provides a constant shielding gas pressure and flow rate during the welding process. Each regulator is designed to be used with a specific gas or mixture of gases. The argon and argon mixture use the same thread type. The 100% carbon dioxide uses a different thread type. An adapter is available at your local welding gas supplier to change between the two.
www.chpower.com