Troubleshooting the Installation
202 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches, version 4.5
Mis-configuration Use the show port CLI
command to show the port
parameters and check they are
compatible with the attached
device.
Faulty NIC Replace the NIC
Connected device does not receive power from switch (C360-PWR
only)
Tip:
Tip: Use the show powerinline CLI command to show
PoE status
Device connected is
not a PD (powered
device), such as a
computer
(PoE LED blinks)
Check that the cable to the PD is
inserted and connected correctly
PD not connected
properly (PoE LED
blinks)
PD not compatible
(PoE LED blinks)
Switch Inline power
capacity exceeded
(PoE LED blinks)
Increase the priority of the PD
port to High or Critical (see page)
Move the PD to a
higher-numbered port
Disconnect unnecessary PDs
from the switch.
Connect an additional Inline DC
power source to the switch
Overcurrent or
undercurrent detected.
Check that the PD is working
correctly.
Table35: Troubleshooting 2 of 3
Problem/Cause Suggested Solution
2 of 3