Installation
36 Installation and Configuration Guide Avaya C360 Multilayer Stackable Switches, version 4.5
Site PreparationYou can mount the C360 alone or in a stack in a standard 19-inch equipment rack located in a
wiring closet or equipment room. You can build a logical stack of up to ten C360 switches.
Ensure that the location where you install your Replace variable w/ short product name fulfills
the following requirements:
●Cables are away from sources of electrical noise such as:
●radio transmitters
●broadcast amplifiers
●power lines
●fluorescent light fixtures
●Water or moisture cannot enter the chassis.
●Air can flow freely around all sides of the chassis.
●The vents on the sides of the chassis are not blocked.
●The environmental conditions match the requirements listed in Tabl e 6.
Table6: Environmental Requirements
Condition Acceptable values
Ambient temperature 32o to 104oF (0o to 40oC)
Relative humidity 5-95% non-condensing
Weight support 10.8-15 lbs (4.9-6.8 kg)