Connecting a BUPS
Issue 1 July 2006 55
Sample Backup Power Supply Scheme
Figure 19 shows a connection example for a stack of three C363T-PWR switches. This
configuration provides power supply redundancy and up to 305 W of inline power per
C363T-PWR switch. Table9 lists the equipment required for this scenario.
Figure 19: Sample Scheme
Figure notes:
1. AC power
2. BUPS DC input (+)
3. BUPS DC input (-)
Table9: Required Equipment (C363T-PWR Scheme) 1 of 2
Quantity Description Material code PEC Code
3 C363T-PWR Power over
Ethernet Stackable Switch 700305881
1 Powerstax Front End AC-DC
Power Shelf R2400A111*
1 of 2
2 31