Problems with Scanned Images

Streaked or unclear images may result if the transparent delivery guide sheet, which is located in the image scanning field, or the white calibration plate beneath it, are dirty or damaged.

Follow the procedures below to clean or replace them.

Cleaning the Delivery Guide Sheet

1.Unplug the scanner and ADF power cords from the electrical outlet.

2.Lift up the ADF on its hinges.

3.Lightly wipe the outside of the delivery guide sheet and the white calibration plate with a soft, dry cloth to remove the dirt.

Delivery Guide Sheet

White Calibration Plate

Never use alcohol, thinners or

benzene to clean the equipment.

53