23XL 50/60 Hz Hermetic Screw Liquid Chillers
SAFETY CONSIDERATIONS
Installation Instructions
With HCFC-22and HFC-134a
INSTALLATION START-UPREQUEST
CONTENTS
INSTALLATION Receiving the Machine
INTRODUCTION
FRONT VIEW
REAR VIEW
Rigging the Machine Ð The 23XL can be rigged as an entire assembly. It also has ¯anged connections that allow the compressor, cooler, condenser, and oil separator sections to be separated to fulll specic installation requirements
Suggested ``I Beam Spreader Bar
Suggested ``I Beam Spreader Bar²
Fig. 5 Ð Machine Rigging Guide Frame 4 Machines
Fig. 6 Ð 23XL Dimensions Frame 1 and 2 Machines
23-22
Fig. 7 Ð 23XL Dimensions Frame 4 Machines
Table 3 Ð 23XL Motor Weights
Table 1 Ð 23XL Compressor Weights
Table 2 Ð 23XL Component Weights
Table 4 Ð 23XL Heat Exchanger Weights
Table 6 Ð 23XL Machine Rigging Weights
2.Disconnect and/or cut the following lines
Refer to Fig. 10 unless otherwise specied
Fig. 9 Ð 23XL Top View Frame 1 and 2 Machines
Fig. 10 Ð 23XL Top View Frame 4 Machines
Fig. 12 Ð Oil Separator Section
Fig. 11 Ð Motor Cooling Drain Section
Frame 4 Machines
Frame 4 Machines
Install Machine Supports
Fig. 14 Ð 23XL Machine Footprint Frame 4 Machine
Fig. 16 Ð Accessory Isolation
Fig. 15 Ð Standard Isolation
Connect Piping
Fig. 18 Ð Typical Low Prole Isolation Assembly
Field Supplied and Installed
Fig. 19 Ð Typical Nozzle Piping
Fig. 20 Ð Piping Flow Data Frame 1 and
Cooler and Condenser Nozzle Arrangements
Waterbox Nozzle Sizes
Waterbox Nozzle Sizes
Fig. 21 Ð Piping Flow Data Frame
Cooler and Condenser Nozzle Arrangements
DIMENSIONS
RATED DRY WEIGHT AND REFRIGERANT CAPACITY
LEGEND Hidden Piping
Field Supplied and Installed Piping
Factory Supplied and Installed Piping
LEGEND Field Supplied and Installed Piping
Factory Supplied and Installed Piping
Table 7 Ð Relief Device Locations
Fig. 25 Ð Pumpout Unit
Fig. 26 Ð Typical 23XL Relief Valve Tree
Connect only 24 v wiring to the control center
LEGEND 1Ð Chilled Water Pump Starter
LEGEND 1Ð Chilled Water Pump Starter
Communication Bus Wiring
Fig. 30 Ð Carrier Comfort Network
Install Field Insulation
23XL CHILLER
LEGEND Factory Wiring Field Wiring
23XL CHILLER
23XL CHILLER
Page
Page
Copyright 1994 Carrier Corporation
INSTALLATION START-UPREQUEST CHECKLIST
TESTING