Carrier 30XW325-400 manual Model number nomenclature, Quality Assurance, a30-4744

Models: 30XW325-400

1 32
Download 32 pages 43.36 Kb
Page 5
Image 5
Model number nomenclature

Model number nomenclature

 

 

 

30XW

325

6

– –

– 4 – 3 B

 

 

30XW – AquaForce® Water-Cooled

 

 

 

 

Packaging/Charging Options

 

 

 

Screw Chiller

 

 

 

 

B

R-134a Refrigerant with Bag (Std)

 

 

 

 

 

 

 

 

C

R-134a Refrigerant with Crate Over Bag

 

 

 

 

 

 

 

 

D

Nitrogen Refrigerant with Bag

Design Series

 

 

 

 

F

Nitrogen Refrigerant with Crate Over Bag

Unit Size (Nominal Tons) (kW)

 

 

 

 

Controls/Communications Options

325 – 325 (1133)

 

 

 

 

-

Navigator™ Display

350 – 350 (1206)

 

 

 

 

0

Navigator Display, EMM

400 – 400 (1354)

 

 

 

 

1

Navigator Display, GFCI Service Option

 

 

 

 

 

 

 

 

2

Navigator Display, EMM, GFCI Service Option

Voltage

 

 

 

 

3

Touch Pilot™ Display (Std)

 

 

 

 

4

Touch Pilot, EMM

1

575-3-60

 

 

 

 

5

Touch Pilot, GFCI Service Option

2

380-3-60

 

 

 

 

6

Touch Pilot, EMM, GFCI Service Option

4

230-3-60

 

 

 

 

7

Navigator Display, BACnet™ Translator

6

460-3-60

 

 

 

 

8

Navigator Display, EMM, BACnet Translator

7

200-3-60

 

 

 

 

9

Navigator Display, GFCI Service Option,

 

 

 

 

 

 

 

 

B

BACnet Translator

Condenser Options

 

 

 

 

Navigator Display, EMM, GFCI Service Option,

 

 

 

 

 

 

BACnet Translator

-

2

Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)

C

Touch Pilot Display (Std), BACnet Translator

0

2

Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections

 

D

Touch Pilot Display, EMM, BACnet Translator

1

2

Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections

 

F

Touch Pilot Display, GFCI Service Option,

2

2

Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections

 

 

 

 

BACnet Translator

3

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections

 

G

Touch Pilot Display, EMM, GFCI Service Option,

4

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections

 

 

 

BACnet Translator

5

2

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections

 

H

Navigator Display, LON Translator

6

2

Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections

 

 

J

Navigator Display, EMM, LON Translator

7

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections

 

K

Navigator Display, GFCI Service Option,

8

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections

 

 

 

LON Translator

9

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections

 

L

Navigator Display, EMM, GFCI Service Option,

B

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections

 

 

 

LON Translator

C

2

Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections

 

M

Touch Pilot Display (Std), LON Translator

D

2

Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections

 

N

Touch Pilot Display, EMM, LON Translator

F

2

Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections

 

P

Touch Pilot Display, GFCI Service Option,

G

2

Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections

 

 

 

LON Translator

H

1

Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving

 

 

Q

Touch Pilot Display, EMM, GFCI Service

J

1

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving

 

 

 

 

Option, LON Translator

K– 1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving

L– 1 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving

 

 

 

 

Electrical Options

Heat Machine

-

Single Point, XL Starter, Terminal Block

0

 

(Std 380, 460, 575-v)

-

Std Condenser/Comfort Cooling (Std)

Single Point, Wye-Delta Starter, Terminal

M – Heat Machine Condenser/Comfort Cooling

3

Block (Std 200,230-v)

 

 

 

 

Dual Point, XL Starter, Terminal Block

 

 

 

 

4

Dual Point, Wye-Delta Starter, Terminal Block

Evaporator Options

7

Single Point, XL Starter, Non-Fused Disconnect

-

2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)

8

Single Point, Wye-Delta, Non-Fused Disconnect

0

2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections

C

Dual Point, XL Starter, Non-Fused Disconnect

1

2 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections

D

Dual Point, Wye-Delta Starter, Non-Fused

2

2

Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections

H

Disconnect

3

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections

Single Point, XL Starter, Terminal Block, CPT

4

2

Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections

J

Single Point, Wye-Delta Starter, Terminal

5

2

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections

M

Block, CPT

6

2

Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections

Dual Point, XL Starter, Terminal Block, CPT

7

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections

N

Dual Point, Wye-Delta Starter, Terminal

8

2

Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections

R

Block, CPT

9

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections

Single Point, XL Starter, Non-Fused

B

2

Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections

S

Disconnect, CPT

C

2

Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections

Single Point, Wye-Delta, Non-Fused

D

2

Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections

 

 

Disconnect, CPT

F

2

Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections

W – Dual Point, XL Starter, Non-Fused

G

2

Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections

X

Disconnect, CPT

H

1

Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving

Dual Point, Wye-Delta Starter, Non-Fused

J

1

Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving

 

 

Disconnect, CPT

K– 1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving

L– 1 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving

 

M – 3 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving

Refrigeration Circuit Options*

 

N

3 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Leaving

4

Standard Unit

 

P

3 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving

6

With Suction Service Valves

 

Q – 3

Pass, NIH, 300 psig (2068 kPa), Flange, Suction Leaving

D – With Minimum Load Control

 

R – 3

Pass, MWB, 150 psig

(1034 kPa), Flange, Discharge Leaving

G – With Suction Service Valves and Minimum

 

S – 3

Pass, MWB, 150 psig

(1034 kPa), Flange, Suction Leaving

 

Load Control

 

T – 3

Pass, MWB, 300 psig

(2068 kPa), Flange, Discharge Leaving

N – With Condenser Insulation for Heat Machine

 

V – 3 Pass, MWB, 300 psig

(2068 kPa), Flange, Suction Leaving

Q – With Suction Service Valves and Condenser

 

 

 

 

 

 

 

 

Insulation for Heat Machine

 

 

 

LEGEND

 

 

X – With Minimum Load Control and Condenser

CPT

Control Power Transformer

 

MWB

Marine Waterbox

 

Insulation for Heat Machine

 

Z – With Suction Service Valves, Minimum Load

EMM

Energy Management Module

NIH

Nozzle-In-Head

 

Control and Condenser Insulation for

GFCI

Ground Fault Circuit Interrupter

XL

Across-the-Line Start

 

 

Heat Machine

LON — Local Operating Network

 

 

 

 

 

 

 

 

 

*Evaporator insulation is standard.

 

 

 

 

a30-4744

Quality Assurance

Certified to ISO 9001:2000

5

Page 5
Image 5
Carrier 30XW325-400 manual Model number nomenclature, Quality Assurance, a30-4744