Table 1D Ð 40RM Physical Data, SI

UNIT 40RM

 

007

 

008

 

012

014

 

016

 

 

024

 

028

 

034

NOMINAL CAPACITY (kW)

 

21

 

26

 

35

43

 

52

 

 

70

 

87

 

105

OPERATING WEIGHT (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Base Unit with TXV

 

173

 

175

 

184

304

 

311

 

 

313

 

463

 

467

Plenum

 

44

 

44

 

44

 

63

 

63

 

 

 

63

 

82

 

82

FANS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

...Qty Diam. (mm)

1

...381

1

...381

...1

...2

2

...381

 

 

...2

...2

...2

Nominal Air¯ow (L/s)

1133

1604

1888

2360

2831

 

 

3775

4719

5663

Air¯ow Range (L/s)

850-1416

1203-2006

1416-2360

1770-2949

2124-3539

 

2831-4719

3539-5899

4247-7079

Nominal Motor kW (Standard Motor)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-1-60

 

0.97

 

1.79

 

Ð

Ð

 

Ð

 

 

Ð

 

Ð

 

Ð

 

208/230-3-60 and 460-3-60

 

1.79

 

1.79

1.79

2.16

 

2.76

 

 

3.73

5.60

7.46

575-3-60

 

0.75

 

1.49

1.49

2.24

 

2.24

 

 

3.73

5.60

7.46

230-3-50, 400-3-50

 

1.79

 

1.79

2.16

2.16

 

2.16

 

 

3.73

5.60

7.46

Motor Speed (r/s)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

208/230-1-60

 

28.8

 

28.8

 

Ð

Ð

 

Ð

 

 

Ð

 

Ð

 

Ð

 

208/230-3-60 and 460-3-60

 

28.8

 

28.8

28.8

28.8

 

28.8

 

 

29.1

29.1

29.1

575-3-60

 

28.8

 

28.8

28.8

28.8

 

28.8

 

 

29.1

29.3

29.3

230-3-50, 400-3-50

 

23.8

 

23.8

23.8

23.8

 

23.8

 

 

23.8

23.8

23.8

REFRIGERANT

 

 

 

 

 

 

 

R-22

 

 

 

 

 

 

 

 

 

Operating charge (kg)

 

1.36

 

1.36

0.68/0.68

0.90/0.90

1.13/1.13

 

 

1.59/1.59

2.04/2.04

2.27/2.27

(approx per circuit)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIRECT-EXPANSION COIL

 

 

 

Enhanced Copper Tubes, Aluminum Sine-Wave Fins

 

 

 

Max Working Pressure (kPag)

 

 

 

 

 

 

 

2999

 

 

 

 

 

 

 

 

 

Face Area (sq m)

 

0.62

 

0.77

0.93

0.93

 

1.64

 

 

1.85

2.30

2.77

No. of Splits

 

1

 

1

 

2

 

2

 

2

 

 

 

2

 

2

 

2

No. of Circuits per Split

 

12

 

15

 

9

 

9

 

12

 

 

13

 

15

 

18

...Split Type Percentage

 

Ð

 

Ð

 

 

 

 

 

...Face

 

50/50

 

 

 

 

 

...Rows Fins/m

3

...591

3

...591

...3

...3

3

...591

 

 

...3

...3

...3

STEAM COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Working Pressure (kPag at 204.4 C)

 

 

 

 

 

 

 

1207

 

 

 

 

 

 

 

 

 

Total Face Area (sq m)

 

0.62

 

0.62

0.62

1.24

 

1.24

 

 

1.24

1.39

1.39

Rows...Fins/m

1

...355

1

...355

1...

355

1...

394

1

...394

 

 

1...

394

1...

394

1...

394

HOT WATER COIL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Max Working Pressure (kPag)

 

 

 

 

 

 

 

1034

 

 

 

 

 

 

 

 

 

Total Face Area (sq m)

 

0.62

 

0.62

0.62

1.24

 

1.24

 

 

1.24

1.39

1.39

Rows...Fins/m

2

...335

2

...335

2...

335

2...

335

2

...335

 

 

2...

335

2...

493

2...

493

Water Volume

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(L)

 

 

 

31.4

 

 

 

 

 

52.6

 

 

 

 

 

54.1

 

(m3)

 

 

 

0.031

 

 

 

 

0.052

 

 

 

 

 

0.054

 

PIPING CONNECTIONS,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantity...Size (in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DX Coil Ð Suction (ODF)

...1 11¤8

...1 11¤8

...2

...2

...2 11¤8

 

 

2...11¤8

...2

...2

DX Coil Ð Liquid Refrigerant (ODF)

 

...1

5¤8

 

 

 

 

 

 

...2

 

5¤8

 

 

 

 

 

Steam Coil, In (MPT)

 

1...

21¤2

 

 

 

 

 

 

1...21¤2

 

 

 

 

Steam Coil, Out (MPT)

 

1...

11¤2

 

 

 

 

 

 

1...11¤2

 

 

 

 

 

Hot Water Coil, In (MPT)

 

...1 11¤2

 

...1 11¤2

 

 

 

 

 

...1

 

 

 

 

Hot Water Coil, Out (MPT)

 

1...

11¤2

 

1...

11¤2

 

 

 

 

 

1...

2

 

 

 

 

Condensate (PVC)

 

 

 

 

 

 

...1

 

 

 

 

 

 

 

 

FILTERS

 

 

 

 

 

Throwaway Ð Factory Supplied

 

 

 

 

 

Quantity...Size

 

4...

406 x 610 x 51

 

 

...4

406 x 508 x 51

 

...4 508 x 610 x 51

 

 

 

4...

406 x 610 x 51

 

4 508 x 635 x 51

Access Location

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Either Side

 

 

 

 

 

 

 

 

LEGEND

TXV Ð Thermostatic Expansion Valve *Units are shipped without refrigerant charge.

5

Page 5
Image 5
Carrier 40RMQ, 40RMS installation instructions Ð 40RM Physical Data, SI, Unit 40RM