58PHA

Table 5 – Air Delivery - CFM (With Filter)*

UNIT SIZE

RETURN---AIR

SPEED

 

 

 

EXTERNAL STATIC PRESSURE (In. wc)

 

 

 

SUPPLY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.1

0.2

0.3

 

0.4

0.5

0.6

0.7

 

0.8

0.9

1

 

 

5

1185

1145

1115

 

1075

1035

980

905

 

820

720

580

045---08/

Bottom or

4

920

880

835

 

800

755

720

680

 

645

605

540

3

735

685

625

 

585

530

490

435

 

395

345

295

024045

Side(s)

 

 

2

820

765

725

 

670

630

580

545

 

490

455

405

 

 

 

 

 

 

1

650

595

535

 

490

430

390

330

 

280

235

--- ---

 

 

5

1625

1585

1535

 

1495

1460

1415

1365

 

1295

1220

1125

070---16 /

Bottom or

4

1405

1360

1320

 

1280

1240

1195

1155

 

1115

1070

1030

3

1240

1200

1155

 

1110

1065

1020

975

 

935

895

850

048070

Side(s)

 

 

2

1190

1140

1095

 

1050

1000

955

915

 

870

830

790

 

 

 

 

 

 

1

1035

985

930

 

885

835

785

745

 

695

650

600

 

 

5

1845

1800

1755

 

1710

1665

1595

1500

 

1400

1275

1105

090---16 /

Bottom or

4

1590

1545

1500

 

1455

1410

1365

1315

 

1270

1180

1000

3

1365

1320

1270

 

1215

1170

1125

1070

 

1025

955

900

048090

Side(s)

 

 

2

1225

1160

1110

 

1060

1010

950

895

 

830

770

710

 

 

 

 

 

 

1

1100

1030

960

 

875

805

730

645

 

570

505

425

 

 

5

2255

2205

2150

 

2100

2040

1985

1920

 

1835

1735

1615

110---20 /

Bottom or

4

1600

1525

1465

 

1400

1335

1275

1210

 

1150

1080

1015

3

1945

1890

1830

 

1770

1715

1655

1600

 

1545

1480

1430

060110

Side(s)

 

 

2

1420

1340

1280

 

1200

1140

1065

1005

 

925

865

790

 

 

 

 

 

 

1

1280

1205

1140

 

1055

990

910

840

 

760

695

630

 

 

5

2295

2240

2185

 

2125

2070

2005

1925

 

1805

1670

1545

135---20 /

Bottom or

4

1725

1660

1605

 

1545

1460

1395

1340

 

1285

1230

1170

Side(s)

 

 

 

 

 

 

 

 

 

 

 

 

 

3

1910

1865

1800

 

1745

1685

1610

1545

 

1485

1435

1380

060135

 

 

 

2

1630

1575

1510

 

1435

1365

1300

1245

 

1185

1130

1065

 

 

 

 

 

 

1

1430

1355

1285

 

1200

1125

1075

1015

 

945

855

800

*A filter is required for each return ---air inlet. Airflow performance included 3/4---in. (19 mm) washable filter media such as contained in factory ---authorized

accessory filter rack. To determine airflow performance without this filter, assume an additional 0.1 in. wc available external static pressure.

 

 

--- --- Indicates unstable operating conditions.

 

 

 

 

 

 

 

 

 

 

 

 

Table 6 – Maximum Capacity of Pipe*

NOMINAL IRON

INTERNAL

 

 

 

LENGTH OF PIPE --- FT. (M)

 

 

 

 

PIPE

DIAMETER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIZE IN. (mm)

In. (mm)

10

20

30

 

40

50

1/2 (13)

0.622 (16)

175

(53)

120

(37)

97

(30)

 

82

(25)

73

(22)

3/4 (19)

0.824 (21)

360 (110)

250

(76)

200 (61)

 

170 (52)

151 (46)

1 (25)

1.049 (27)

680 (207)

465

(142)

375

(114)

 

320 (98)

285 (87)

1---1/4 (32)

1.380 (35)

1400

(427)

950 (290)

770

(235)

 

660

(201)

580

(177)

1---1/2 (38)

1.610 (41)

2100

(640)

1460

(445)

1180 (360)

 

990

(301)

900

(274)

*Cubic ft. of natural gas per hr for gas pressures of 0.5 psig (14---in. wc) or less and a pressure drop of 0.5---in wc (based on a 0.60 specific gravity gas). Ref: Chapter 6 ANSI Z223---2006/NFPA 54---2006.

Piping should be pressure and leak tested in accordance with NFGC in the United States or CAN/CSA-B149.1-05 in Canada, local, and national plumbing and gas codes before the furnace has been connected. After all connections have been made, purge lines and check for leakage at furnace prior to operating furnace.

If pressure exceeds 0.5 psig (14-in. wc), gas supply pipe must be disconnected from furnace and capped before and during supply pipe pressure test. If test pressure is equal to or less than 0.5 psig (14-in. wc), turn off electric shutoff switch located on furnace gas control valve and accessible manual equipment shutoff valve before and during supply pipe pressure test. After all connections have been made, purge lines and check for leakage at furnace prior to operating furnace.

The gas supply pressure shall be within the maximum and minimum inlet supply pressures marked on the rating plate with the furnace burners ON and OFF.

18

Page 18
Image 18
Carrier 58PHA/PHX instruction manual Air Delivery CFM With Filter, Maximum Capacity of Pipe