58PHA
(664mm) | (733mm) |
| |
| |||
| |||
|
| ||
(FLUE COLLAR) |
|
| |
| (641mm) |
| |
|
| ||
|
| ||
| (573mm) |
| |
| JUNCTION BOX |
| |
LOCATION |
| ||
|
| ||
(135mm) |
|
| |
(22mm) |
|
| |
7/8" DIA |
|
| |
ACCESSORY | 1/2" (13 mm) DIA. |
| |
| THERMOSTAT WIRE ENTRY |
| |
|
| ||
| LEFT HAND GAS |
| |
ENTRY |
| ||
| |||
(846mm) |
| ||
| (632mm) | ||
| 7/8" (22mm) DIA. |
| |
| ACCESSORY |
| |
11/16" | (549mm) | ||
(17mm) | (140mm) | ||
| |||
| BOTTOM INLET | (43mm) | |
| 24" |
| |
| CASING |
| |
| (610mm) |
|
A |
|
|
|
|
| |
|
| (62mm) | AIRFLOW |
|
| |
|
|
|
| |||
D | 13/16" |
| (33mm) | 19" | 13/16" |
|
| (483mm) | (21mm) |
| |||
F | (21mm) | (29mm) | OUTLET |
|
| |
| (122mm) |
|
|
|
| |
|
|
|
| 1/2" DIA. K.O.THERMOSTAT |
| |
|
|
| WIRE ENTRY (13mm) | 11/16" | ||
|
|
| (244mm) | |||
|
| (217mm) | (17mm)(197mm) | |||
|
| GAS ENTRY (44mm) |
| |||
|
|
|
|
|
| |
|
|
|
|
|
| (292mm) |
|
|
|
| 7/8" DIA. K.O. WIRE ENTRY |
|
|
|
| ALTERNAT E | (22mm) |
|
| |
| JUNCTION BOX |
|
|
| ||
| LOCATIONS (TYP) |
|
|
| ||
| VENT OUTLET |
|
|
| ||
| 5 PLACES (TYP) |
|
| |||
|
|
|
| 7/8" DIA. ACCESSORY | (378mm) |
|
|
| (22mm) |
|
| ||
|
|
|
|
| ||
E | 11/16" |
|
| |||
(17mm) |
| (560mm) |
| |||
(95mm) |
| (32mm) |
| |||
|
|
|
| 1" |
| |
|
|
|
| SIDE INLET | (25mm) |
|
|
|
|
| A04037 |
NOTES: |
|
|
| |
1. | Two additional | |||
2. | Minimum return | |||
a. For 800 | in. (406 mm) round or 14 1/2 x | |||
b. For 1200 | in. (508 mm) round or 14 1/2 x 19 | in. (368 x 495 mm) rectangle. | ||
c. For 1600 | in. (559 mm) round or 14 1/2 x 22 | in. (368 x 560mm) rectangle. |
d. For airflow requirements above 1800 CFM, see Air Delivery table in Product Data literature for specific use of single side inlets. The use of both side inlets, a combination of 1 side and the bottom, or the bottom only will ensure adequate return air openings for airflow requirements above 1800 CFM.
Fig. 1 - Dimensional Drawing
Table 1 – Dimensions
|
|
| A |
| D |
| E |
| F | FLUE |
| FILTER | |
|
|
|
|
| C.L. TOP AND | SHIP WT | MEDIA | ||||||
|
| CABINET | SUPPLY AIR | RETURN AIR | |||||||||
FURNACE SIZE | BOTTOM FLUE | COLLAR* | CABINET | ||||||||||
| WIDTH |
| WIDTH |
| WIDTH | (LB / KG) | |||||||
|
|
|
|
| COLLAR | IN. (MM) | SIZE | ||||||
|
| IN. (MM) | IN. (MM) | IN. (MM) |
| ||||||||
|
|
| IN. (MM) |
|
| IN. (MM) | |||||||
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| |
08/024045 | 3/16 (360) | 9/16 (319) | 11/16 (322) | 5/16 (237) | 4 (102) | 114 (52) | 16 (406) | ||||||
16/048070 | 17 | 7/8 (403) |
| 16 (406) | 11 | 4 (102) | 136 (62) | 16 (406) | |||||
16/048090 |
| 21 (533) | 3/8 (492) | 19 | 13 | 4 (102) | 150 (68) | 20 (508) | |||||
20/060110 |
| 21 (533) | 3/8 (492) | 19 | 13 | 4 (102) | 162 (73) | 20 (508) | |||||
20/060135 | 24 | 7/8 (581) |
| 23 (584) | 15 | 4 (102) | 173 (78) | 24 (610) |
* 5 in. or 6 in. (127 or 152 mm) vent connector may be required in some cases.
SAFETY CONSIDERATIONS
!WARNING
FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON MONOXIDE POISONING HAZARD
Failure to follow this warning could result in dangerous operation, serious injury, death, or property damage.
Improper installation, adjustment, alteration, service, maintenance, or use could cause carbon monoxide poisoning, explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified service agency, local gas supplier, or your distributor or branch for information or assistance. The qualified service agency must use only
!CAUTION
FURNACE RELIABILITY HAZARD
Improper installation or misapplication of furnace may require excessive servicing or cause premature component failure.
Application of this furnace should be indoors with special attention given to vent sizing and material, gas input rate, air temperature rise, unit leveling, and unit sizing.
Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause death, personal injury, or property damage. Consult a qualified installer, service agency, or your distributor or branch for information or assistance. The qualified installer or agency must use
Follow all safety codes. Wear safety glasses, protective clothing, and work gloves. Have a fire extinguisher available. Read these
2