User Maintenance

5. Press the [S] key to select “Yes”, and then press the [ENTER] key.

zThis resets the lamp time to 0 hours.

6.Press the [MENU] key to exit the setup menu.

zThis causes the setup menu to disappear from the projected image.

To reset the lamp time after exceeding the lamp life

If you use the existing lamp until its life is exceeded, you will not be able to turn on the projector even after you replace the lamp with a new one. Perform the following procedure to initialize the lamp time in this case, which will make it possible to turn on the projector.

1. Use the bundled AC power cord to plug the projector into a power outlet.

zConnecting to a power outlet causes the POWER/STANDBY and LAMP indicators on the top of the projector to light red, which indicates that the lamp has exceeded its service life.

2.While holding down the projector’s [W] key, hold down the [AUTO] key for about five seconds.

zThis will reset the lamp time, cause the POWER/STANDBY indicator to change from red to amber, and also cause the LAMP indicator to go out.

3.Press the [] (power) key to ensure that the projector turns on normally.

109