MOUNTING CONFIGURATION

FOR STEEL RACK

BOLT USING

WELD

FASTENERS66

MOUNTING

PROVIDED

BRACKET

PROVIDED TO

STEEL RACK

ORIGIN MARKER

BRACKET

66

A

68

 

GREATER THAN 500mm

66

B

 

 

66

C

13-20mm

 

68

MOUNTING OF GATE SENSOR

-With the gate in the CLOSED position, mount the origin marker (66) a minimum 500mm from the origin sensor (68). (See isometric view (A) or plan view (B) above).Please note this distance will affect the pedestrian opening distance. For

minimum pedestrian opening, mount the origin marker at 500mm. The maximum distance of the origin marker is limited by the marker having to pass the sensor by no less than 500mm before the gate opens fully. If a longer crawling distance is required, the position of the marker needs to be changed (see table 3 on page 30).

-Manually slide gate OPEN until origin marker (66) is in line with the origin sensor (68). Ensure distance between face of marker (66) and front face of sensor (68) is between 13 and 20mm. (See (C) above)

-Adjust distance by sliding the origin marker (66) along the slotted mounting holes until desired distance is achieved.